Passage Function

Programming the Passage Function will change the state from locked to unlocked of the PowerLever Door Lock.
When programmed to the unlocked, or Passage function, no combination or key override is required for entry. Only
managerial personnel are authorized to program the Passage Function. The factory default of a new lock is Passage
Function = Off (Locked).

Wrong Try Limit and Penalty Time

The wrong try limit is the maximum number of consecutive failed entry attempts that can occur before the lock tem-
porarily shuts down (to prevent combination tampering). The wrong try limit is programmable from 3-9 with a
default of 3.
The penalty time is the time period for which the lock shuts down when the wrong try limit is reached. The shutdown
time is programmable from 0 to 90 seconds with a factory set default of 20 seconds. Only managerial personnel
are authorized to program these parameters.
During the shutdown period, the lock will not respond to any user actions. If you attempt to power the lock during the
shutdown period, the lock will display two simultaneous flashes of the red LED to indicate an error condition. When
the shutdown period has elapsed the lock will respond to user actions. Each additional wrong try will result in the
lock shutting down for the programmed penalty time. This cycle will continue until a correct combination is entered
for a Keypad User or a valid Smart Key is presented for a Key Access User.

Audit Features

Audit features require the PowerLever software to report on the audit and user information retrieved from the lock. If
you have purchased the PowerLever Door Lock PC software for reporting capabilities, data stored in the lock can be
read from the lock and taken to the PC for reporting. See the PowerLever Door Lock Software Reference Manual for
more detail.

Retrieve Audit Records

The lock's audit feature will track the following types of lock transactions in sequential order of occurrence:
• lock user table configured (i.e., number of Smart Key
users and Keypad User PIN field length)
• lock opened
• lock activated
• lock shelved
• PIN / combination changed
• add User ID
• delete User ID
• user enabled
• user disabled
• re-lock / wrong try penalty time set
• failed attempts penalty
• audit report retrieved
• set date/time
• Daylight Savings Time ON
10
• Standard Time ON
• holiday / Daylight Savings Time changeover data
loaded to lock
• Service User activated
• Audit User activated
• Access User report retrieved
• Passage Mode ON
• Passage Mode OFF
• Manager User activated
• Manager User deactivated
• Master combination reset via hardware button
• lock disabled to Access Users and Service Users
• lock enabled to Access Users and Service Users
• Palm handheld connect
• Palm handheld disconnect