Step
3.
Press
then 50.
4.
Enter new Master User
combination.
Note: The User ID selected must be in the range from 0 to the number of keypad users minus one.
Note:When PIN length = 0, Combination = User ID only; otherwise, Combination = User ID + PIN.
5.
Enter Master User
combination again.

Activate a Manager User

Note: As many Manager Users can be activated as there are available keypad user table spaces in the lock.
Step
1.
Power lock.
2.
Enter Master User
combination.
3.
Press
then 90.
4.
Enter Manager User
combination.
Note: The User ID selected must be in the range from 0 to the number of keypad users minus one.
5.
Enter Manager User
combination again.
Detailed Instructions
Before re-lock time expires, press
then the 0 key. The lock responds with two beeps/flashes of the green LED.
Enter the new Master User combination. The lock responds with two beeps/
flashes of the green LED.
Enter the Master User's new combination again for verification. The lock
responds with two simultaneous beeps/flashes of the green and red LEDs if
the combination was verified successfully. The lock responds with two
beeps/flashes of the red LED to indicate an error.
The lock is now activated and the new Master User combination is in effect.
Detailed Instructions
Power the lock by depressing the outside lever.
Enter the Master User combination. The lock will beep/flash the green LED
on each keystroke entered. If the Clear key is pressed during data entry, the
lock responds with one alternate beep/flash of the green and red LED, and
all digits of the combination must be re-entered.
The lock responds with three beeps/flashes of the green LED to indicate
available entry. If the combination is not valid, the lock responds with three
beeps/flashes of the red LED.
Before re-lock time expires, press
then the 0 key. The lock responds with two beeps/flashes of the green LED.
Enter the combination for the Manager User. The lock responds with two
beeps/flashes of the green LED.
Enter the Manager User combination again for verification. The lock
responds with two simultaneous beeps/flashes of the green and red LEDs if
the combination was verified successfully. The lock responds with two
beeps/flashes of the red LED to indicate an error.
If PIN length > 0, the Manager User must change his PIN in order to activate
his combination.
(Enter key) followed by the 5 key and
(Enter key) followed by the 9 key and
15