  • Page 1 5X10 EXIT TRIM MODELS INSTALLATION INSTRUCTIONS...
  • Page 2: Table Of Contents

    Warnings and Cautions Important: Carefully inspect windows, doorframe, door, lights, etc. to ensure that the recommended procedures will not cause damage. Kaba Access Control’s warranty does not cover damages caused by installation. Caution: Wear safety glasses when preparing door.
  • Page 3 E-PLEX 5x10 Exit Trim Model The E-Plex Exit Trim Lock is adapt- able to a wide variety of the more popular exit devices on the market today. No tools are required to reverse handing, and the spring loaded tailpiece drive automatical-...
  • Page 4: Tools Required

    OPERATIONAL NOTE: The E-Plex Exit Trim lock is almost identical to the E-Plex 5000 Cylindrical lock with the following exceptions: 1. Operation of the Lever When the lock’s handing is properly set, only a downward rotation of lever will actuate latch. 2.
  • Page 5: Door Preparation - Exit Device

    A. DOOR PREPARATION - EXIT DEVICE A-1 For New Installations (Existing Installations proceed to Step A-2): For new installations, all mounting hardware for the actual exit device should be acquired from the exit device supplier. All necessary hardware to mount the E-Plex exit trim is included in the box. The rim style exit device determines the location of the Vertical and Horizontal Centerlines.
  • Page 6: Install Exit Device

    B. DOOR PREPARATION – E-PLEX EXIT TRIM B-1 For New Installations (Existing Installations proceed to Step B-2): Place paper template (e) (supplied) onto the inside of the door and align with the Centerlines. Mark the location of the E-Plex Exit Trim mounting holes.
  • Page 7: Door Thickness

    D. DOOR THICKNESS The E-Plex Exit Trim Drive Unit (a) has a spring loaded tailpiece (b) and is preassembled to accom- modate standard door thickness from 1 ⁄ " to approximately 2 ⁄ " for most applications. For Doors up to 2 ⁄...
  • Page 8 5x00 SERIES LIMITED WARRANTY Kaba Access Control warrants this product to be free from defects in material and workmanship under normal use and service for a period of three (3) years. Kaba Access Control will repair or replace, at our discretion, 5000 Series Locks found by Kaba Access Control analysis to be defective during this period.
  • Page 11 Notes...
  • Page 12: Changing Key-In-Lever (Kil) Cylinder

    G-2 Determine the proper tailpiece (d) from the chart below for your KIL cylinder. You must use a Kaba tailpiece. The K 2 tailpiece is preassembled with the Kaba 1599. TAILPIECE KIL CYLINDER Abloy 5277, Abloy 5477, Assa 65691, Kaba 1539, Kaba Gemini 4730 Assa 65611, Australian: Kaba experT 107K5 &...
  • Page 13 H. INSTALLING / REMOVING OUTSIDE LEVER (Key-In-Lever models only, for interchangeable and removable cores proceed to section I) Note: Installing levers to the unit Correct Incorrect assemblies before mounting the unit Position Position assemblies may ease initial installation. KIL Lever Sleeve H-1 Make certain the lever catch is up as shown (c).
  • Page 14 Insert the outside lever (b) until it is flush to the outside unit assembly (a). To secure the outside lever, insert the release tool (d) (or screwdriver) into the outside lever as shown, and slide the lever catch down until it clicks. Make certain lever is attached before installing the core.
  • Page 15: Installing E5X00 Exit Trim

    Using two pairs of pliers, break the tailpiece to the desired length of the intended application by holding one pair of pliers on the good side of the score mark and a second pair on the other side of the score mark. Slowly move the 2nd pair of pliers up and down until the unneeded portion of the tailpiece breaks free.
  • Page 16: Installing The Battery Pack And Cover Changing Batteries

    J-4 Insert the LectroBolt through the red battery mounting plate hole marked with the lightning bolt symbol. For now, only partially tighten the LectroBolt enough to hold the Outside Unit assembly and the battery mounting plate in place on the door. J-5 Insert the two Mounting Bushings (f) into the lower two holes on the inside of the door.
  • Page 17: Testing The Operation Of The Lock

    Warning: Do not install a 9V battery. This EPLEX lock operates on 4 alkaline only AA batteries (6V). A 9V will ruin the electronics in the lock and void the warranty. K-3 Remove the four depleted batteries and install four new alkaline (only) AA batteries.
  • Page 18: Reset Function

    M. RESET FUNCTION Warning: When the lock is reset, all existing authorization and access codes are deleted, and the lock is configured to the factory default lock settings. The master code becomes 1,2,3,4,5,6,7,8. If the Master Code is lost or forgotten and the number has not been recorded, the lock can be reset to the factory defaults by following this procedure: 1) Insert key and turn to “open”...