Disable a Group of User IDs

This operation allows the Master User or Manager User to restrict access to an
entire user ID group. See User ID Groups (page 5) for more information.
Note: The Master User and Manager User are not affected by this operation
even though their User ID may be included in the group being disabled.
Step
Detailed Instructions
1.
Power lock.
Power the lock by depressing the outside lever.
2.
Enter Master User
Enter the Master User or Manager User combina-
or Manager User
tion. The lock will beep/flash the green LED on
combination
each keystroke entered. If the Clear key is pressed
during data entry, the lock responds with one beep/
flash of the green LED followed by the red LED, and
all digits of the combination must be re-entered. The
lock responds with three beeps/flashes of the green
LED to indicate available entry. If the combination is
not valid, the lock responds with three beeps/flashes
of the red LED.
3.
Press
then 60.
Before re-lock time expires, press
followed by the 6 key and then the 0 key. The lock
responds with two beeps/flashes of the green LED.
4.
Enter User ID
Enter a User ID group number of 00-20 (00 will
group number of
disable all User IDs). The lock responds with two
00-20.
beeps/flashes of the green LED.
The selected User ID group is disabled. If the
User ID number 00 was chosen to disable all User
IDs, the lock responds with two simultaneous
beeps/flashes of the green and red LEDs.
5.
Repeat Step 4 to
If the User ID number 00 option was not chosen
disable another
to disable all User IDs, repeat Step 4 to disable
group or go to
another group (01-20) or go to Step 6.
Step 6.
6.
Press
to exit.
Press
lock responds with two simultaneous beeps/ flashes
of the green and red LEDs and exits this procedure.
24
(Enter key)
(Enter key) to exit this procedure. The

Enable a Group of User IDs

This operation allows the Master User or Manager User to enable access to a
entire user ID group. See User ID Groups (page 5) for more information.
Step
Detailed Instructions
1.
Power lock.
Power the lock by depressing the outside lever.
2.
Enter Master User
Enter the Master User or Manager User combina-
or Manager User
tion. The lock will beep/flash the green LED on
combination
each keystroke entered. If the Clear key is pressed
during data entry, the lock responds with one beep/
flash of the green LED followed by the red LED, and
all digits of the combination must be re-entered. The
lock responds with three beeps/flashes of the green
LED to indicate available entry. If the combination is
not valid, the lock responds with three beeps/flashes
of the red LED.
3.
Press
then 61.
Before re-lock time expires, press
followed by the 6 key and then the 1 key. The lock
responds with two beeps/flashes of the green LED.
4.
Enter User ID
Enter a User ID group number of 00-20. (00 will
group number of
enable all User IDs.) The lock responds with two
00-20.
beeps/flashes of the green LED.
The selected User ID group is enabled. If the
User ID number 00 was chosen to enable all User
IDs, the lock responds with two simultaneous
beeps/flashes of the green and red LEDs.
5.
Repeat Step 4 to
If the User ID number 00 option was not chosen
enable another
to enable all User IDs, repeat Step 4 to disable
group or go to
another group (01-20) or go to Step 6.
Step 6.
6.
Press
to exit.
Press
lock responds with two simultaneous beeps/ flashes
of the green and red LEDs and exits this procedure.
(Enter key)
(Enter key) to exit this procedure. The
25