Lock Responses; Programmable Features; Lockout; Re-Lock Time - Kaba PowerLever 455 Series Operating Instructions Manual

Table of Contents

Advertisement

Lock Responses

The tables below summarize how the red and green LEDs are flashed individually, simultaneously, or in combination
to indicate various conditions. Each LED flash is accompanied by a beep for audio reinforcement.
Flashes
Green LED
Continuous
SA Key* Required at Reader
1
Keystroke Entry
2
Input Accepted
3
Lock Ready to Open
4
User ID Added/Deleted Manually
* The SA key is used to transfer information between the lock and the PC.
Flashes
Green / Red Sequence
Continuous
Download in Progress
1
CLR Key Depression
2
Device Error **
** Contact Customer Service for assistance.
• One simultaneous flash of the green and red LEDs accompanied by a beep indicates that the lock is powered.
• When power drops below a sufficient level for operation, the lock will continually beep and flash the red LED. At this
point, the operator has 5 seconds in which to regenerate power to a sufficient level before the lock will systematical-
ly shutdown. To regenerate power, depress the outside lever through a 67-degree open and 67-degree restore rota-
tion.
• After each accepted step of an operation, two flashes of the green LED display and two beeps sound, prompting
you to enter additional information for the next step of the operation. The User must wait for these prompts
before proceeding.
• After you have completed all the steps of an operation, two simultaneous flashes of the green and red LED display
and two beeps sound if the operation is successful. Two red flashes display and two beeps sound if the operation is
unsuccessful and you will need to re-key the operation which caused the error.

Programmable Features

The PowerLever Door Lock has the following programmable features.

Lockout

Managerial personnel can control the entry of Access Users and Service Users by enabling and disabling available
entry. Lock entry rights can be programmed for specific users or all Access Users and Service Users.
Note: The Master User and Manager Users are not affected by the lockout.

Re-Lock Time

The re-lock time (i.e. the time that the lock remains open before re-locking) can be programmed by managerial per-
sonnel from 2 to 20 seconds, with a factory set default of 4 seconds. The lock automatically re-locks after the re-lock
time has expired. The re-lock is indicated by an audible "click".
Red LED
Low Power
General Error
Bad Attempt to Open
Simultaneous Green-Red
Lock Powered
Procedure End; Re-lock or Penalty Time Expired