Step
3.
Press
then 50.
4.
Enter new Master User
Note: The User ID selected must be in the range from 0 to the number of keypad users minus one.
Note: When PIN length = 0, Combination = User ID only; otherwise , Combination = User ID + PIN.
5.
Enter new Master User
combination again.

Open the Lock with Combination

Step
1.
Power lock.
2.
Enter combination.
Caution: When opening the lock, do not depress the outside lever until the lock responds with three beeps/flashes
of the green LED to indicate available entry.
Note: After the limit of consecutive failed entry attempts has been reached, the lock will temporarily shut down to
prevent combination tampering for the time programmed by managerial personnel. During the shutdown period,
the lock will not respond to any user actions. When the shutdown period has elapsed the lock can be used normally.
Any additional failed entry attempt results in the lock being disabled again for the programmed shutdown time. This
cycle will continue until a correct combination is entered.
3.
Open lock.
20
Detailed Instructions
Before re-lock time expires, press
then the 0 key. The lock responds with two beeps/flashes of the green LED.
Enter a new Master User combination. The lock responds with two simulta-
neous beeps/flashes of the green LED if the User ID portion of the combina-
tion is unique. The lock responds with two beeps/flashes of the red LED to
indicate an error.
Enter the new Master User combination again for verification. The lock
responds with two simultaneous beeps/flashes of the green and red LEDs if
the combination was verified successfully.
The lock responds with two beeps/flashes of the red LED to indicate an error.
The new combination is now active for the Master User.
Detailed Instructions
Power the lock by depressing the outside lever.
Enter the combination to open the lock. The lock will beep/flash the green
LED on each keystroke entered. If the Clear key is pressed during data
entry, the lock responds with one beep/flash of the green LED followed by
the red LED, and all digits of the combination must be re-entered.
The lock responds with three beeps/flashes of the green LED to indicate
available entry. If the combination is that of an Keypad Access User or
Service User and the User ID has been disabled by managerial personnel,
the lock responds with two beeps/flashes of the red LED. If the combination
is not valid, the lock responds with three beeps/flashes of the red LED.
Before re-lock time expires, depress the outside lever to open the lock. At
the end of the re-lock interval the lock will respond with two simultaneous
beep/flashes of the red and green LEDs.
(Enter key) followed by the 5 key and