Set Lock Time And Date; Set The Re-Lock And Wrong Try Limit And Penalty Times - Kaba PowerLever 455 Series Operating Instructions Manual

Table of Contents

Advertisement

Set Lock Time and Date

This feature enables managerial personnel to set the time and date in the lock.
Note: Only the Master User and Manager Users can set the time and date in the lock.
To set the lock time and date, complete the following steps:
Step
1.
Power lock.
2.
Enter Master User or a
Manager User combination.
3.
Press
then 8.
Note: If you are setting the lock time for the first time since the lock was shipped from the factory, enter the time in
Standard Time, regardless if Daylight Savings Time is in effect or not. Otherwise, enter the current local time.
4.
Enter time in 24-hour format
(HHMMSS).
5.
Enter date (MMDDYY).

Set the Re-Lock and Wrong Try Limit and Penalty Times

Step
1.
Power lock.
2.
Enter Master User or a
Manager User combination.
3.
Press
then 10.
4.
Enter two-digit re-lock time.
5.
Enter one-digit wrong
try penalty.
6.
Enter two-digit wrong
try penalty time.
16
Detailed Instructions
Power the lock by depressing the outside lever.
Enter the Master User or a Manager User Combination. The lock will beep/
flash the green LED on each keystroke entered. If the Clear key is pressed
during data entry, the lock responds with one beep/flash of the green LED
followed by the red LED, and all digits of the combination must be re-
entered. The lock responds with three beeps/flashes of the green LED to
indicate available entry. If the combination is not valid, the lock responds with
three beeps/flashes of the red LED.
Before re-lock time expires, press
The lock responds with two beeps/flashes of the green LED.
Enter a time in the hh:mm:ss 24-hour format (i.e. hour has range of 00–23).
For example, a time of 1:30:10 PM would be entered as 133010. The lock
responds with two beeps/flashes of the green LED.
Enter a date in the mm:dd:yy format. For example, a date of August 30,
1997 would be entered as 083097. The lock responds with two simultaneous
beeps/flashes of the green and red LEDs.
The entered lock time and date are now in effect.
Detailed Instructions
Power the lock by depressing the outside lever.
Enter the Master User or a Manager User Combination. The lock will beep/
flash the green LED on each keystroke entered. If the Clear key is pressed
during data entry, the lock responds with one beep/flash of the green LED
followed by the red LED, and all digits of the combination must be re-
entered. The lock responds with three beeps/flashes of the green LED to
indicate available entry. If the combination is not valid, the lock responds with
three beeps/flashes of the red LED.
The lock responds with three beeps/flashes of the green LED to indicate
available entry. If the combination is not valid, the lock responds with three
beeps/flashes of the red LED.
Before re-lock time expires, press
then the 0 key. The lock responds with two beeps/flashes of the green LED.
Enter a new two-digit re-lock time in the range of 02-20 seconds. The lock
responds with two beeps/flashes of the green LED.
Enter a new one-digit wrong try penalty limit in the range of 3-9 tries. The
lock responds with two beeps/flashes of the green LED.
Enter a new two-digit wrong try penalty time in the try range of 00-90
seconds. The lock responds with two simultaneous beeps/flashes of the
green and red LEDs.
The re-lock time and wrong try limit and penalty time are now in effect.
(Enter key) followed by the 8 key.
(Enter key) followed by the 1 key and

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerlever 4550

Table of Contents