Open the Lock with Access User Key

Step
1.
Power lock.
2.
Insert Access User Key into
key reader.
Note: If the number of consecutive wrong tries defined in the lock is reached by repeatedly inserting an incorrect
key, the lock will shut down for the defined penalty time. During the shutdown period, the lock will not respond to
any user actions. When the shutdown period has elapsed the lock can be used normally. Any additional failed entry
attempt results in the lock being disabled again for the programmed shutdown time. This cycle will continue until a
valid key is inserted.
3.
Enter Key Access User PIN.
Note: If the number of consecutive wrong tries for PIN entry defined in the key is exceeded, the Access User Key is
invalidated for use.
Caution: When opening the lock, do not depress the outside lever until the lock responds with three beeps/flashes
of the green LED to indicate available entry.
4.
Open lock.

Issue Service User Combination

This operation issues a one-time combination for a Service User that can be used to open the lock.
Note: As many Service Users can be activated as there are available keypad user table spaces in the lock.
Step
1.
Power lock.
2.
Enter Master User or a
Manager User combination.
3.
Press
then 92.
Detailed Instructions
Power the lock by depressing the outside lever.
Insert the Access User Key into the lock key reader. If the Access User Key
is programmed to not require a PIN (PIN length =0), the lock responds with
three beeps/flashes of the green LED to indicate available entry. Go to step
4. If the Key is that of an Access User whose has been disabled by manage-
rial personnel, the lock responds with two beeps/flashes of the red LED. If
the Access User Key is not valid, or if a holiday is in effect, or if the Key
Access User's time windows do not allow entry at the time that the key is
applied, the lock responds with three beeps/flashes of the red LED.
If the Access User Key is programmed to require a PIN, the lock responds
with two beeps/flashes of the green LED.
Enter the four–digit PIN for the Key Access User. The lock responds with
three beeps/flashes of the green LED to indicate available entry. If the lock
PIN is not valid, the lock responds with two beeps/flashes of the red LED.
(Note: For a User who has not changed the default PIN, the lock will not open.)
Before re-lock time expires, depress the outside lever to open the lock. At
the end of the re-lock interval the lock will respond with two simultaneous
beep/flashes of the red and green LEDs.
Detailed Instructions
Power the lock by depressing the outside lever.
Enter the Master User or a Manager User combination. The lock will beep/
flash the green LED on each keystroke entered. If the Clear key is pressed
during data entry, the lock responds with one beep/flash of the green LED
followed by the red LED, and all digits of the combination must be re-
entered.
The lock responds with three beeps/flashes of the green LED to indicate
available entry. If the combination is not valid, the lock responds with three
beeps/flashes of the red LED.
Before re-lock time expires, press
then the 2 key. The lock responds with two beeps/flashes of the green LED.
(Enter key) followed by the 9 key and