Determine Model Type

This feature provides identification of the model type, i.e., Model 455x. To determine the model type, complete the fol-
lowing steps:
Step
1.
Power lock.
2.
Enter Master User or a
Manager User combination.
3.
Press
then 11.
Switch Passage Function (Off / On)
This operation allows Passage Function to be toggled Off and On.
Step
1.
Power lock.
2.
Enter Master User or a
Manager User combination.
3.
Press
then 16.

Toggle Lock Enabled / Disabled Status

Note:When the lock is disabled, all Access Users and Service Users are prohibited from using the lock.
Step
1.
Power lock.
2.
Enter Master User or a
Manager User combination.
3.
Press
then 13.
Detailed Instructions
Power the lock by depressing the outside lever.
Enter the Master User or a Manager User combination. The lock will beep/
flash the green LED on each keystroke entered. If the Clear key is pressed
during data entry, the lock responds with one beep/flash of the green LED
followed by the red LED, and all digits of the combination must be re-
entered.
The lock responds with three beeps/flashes of the green LED to indicate
available entry. If the combination is not valid, the lock responds with three
beeps/flashes of the red LED.
Before re-lock time expires, press
then the 1 key again. The lock responds with beeps/flashes of the green
LED corresponding to the model type as follows:
4 beeps/flashes – Model 455x
Detailed Instructions
Power the lock by depressing the outside lever.
Enter the Master User or a Manager User combination. The lock will beep/
flash the green LED on each keystroke entered. If the Clear key is pressed
during data entry, the lock responds with one beep/flash of the green LED
followed by the red LED, and all digits of the combination must be re-
entered. The lock responds with three beeps/flashes of the green LED to
indicate available entry. If the combination is not valid, the lock responds with
three beeps/flashes of the red LED.
Before re-lock time expires, press
then the 6 key. The lock responds with two beeps/flashes of the green LED.
If Passage mode was Off, it is now On. If Passage mode was On, it is now Off.
Detailed Instructions
Power the lock by depressing the outside lever.
Enter the Master User or a Manager User combination. The lock will beep/
flash the green LED on each keystroke entered. If the Clear key is pressed
during data entry, the lock responds with one beep/flash of the green LED
followed by the red LED, and all digits of the combination must be re-
entered. The lock responds with three beeps/flashes of the green LED to
indicate available entry. If the combination is not valid, the lock responds with
three beeps/flashes of the red LED.
Before re-lock time expires, press
then the 3 key. The lock responds with two beeps/flashes of the green LED.
The lock status has now been toggled from enable to disable or from disable
to enable.