Add Keypad Access User(s)

Note: You do not need to perform this operation if you are downloading users from the PC.
Note: If at any time during the procedure the lock power drops below a sufficient level for operation, the lock will
continually beep and flash the red LED, prompting the user to depress the outside lever to provide additional power
within 5 seconds.
Step
1.
Power lock.
2.
Enter Master User or a
Manager User combination.
3.
Press
then 2.
4.
Enter Keypad Access User ID.
Note: The User ID selected must be in the range from 0 to the number of keypad users minus one.
5.
Enter Access User ID again.
6.
Enter one-digit user access
schedule.
Note: If the value of "0" is assigned for the access schedule, the Keypad Access User can access the lock at all
times. To assign a value other than "0", defined access schedules must have been down loaded from the PC.
7.
Repeat Steps 4–6 to add
more users or go to Step 8.
Caution: If you are adding multiple Keypad Access Users, you may need to depress the outside lever to provide
additional power.
8.
Press
.
Note: If PIN length is not 0, a default PIN of all 0's is assigned to the new Access User. The Access User must
change this default PIN before the Access User's combination can be used to open the lock. Refer to the "Change
PIN" section for instructions on changing an Access User's PIN.
Note: To change an access schedule assignment for a user at the lock, the user must first be deleted and then re-
added to the lock with the new schedule assignment. The other method to change an access schedule occurs at the
PC and requires downloading of the users into the lock again after the change has been made at the PC.
Detailed Instructions
Power the lock by depressing the outside lever.
Enter the Master User or a Manager User combination on the lock keypad.
The lock will beep/flash the green LED on each keystroke entered. If the
Clear key is pressed during data entry, the lock responds with one beep/
flash of the green LED followed by the red LED, and all digits of the combi-
nation must be re-entered.
The lock responds with three beeps/flashes of the green LED to indicate
available entry. If the combination is not valid, the lock responds with three
beeps/flashes of the red LED.
Before re-lock time expires, press
The lock responds with two beeps/flashes of the green LED.
Enter a User ID for a Keypad Access User. The lock responds with two
beeps/flashes of the green LED if the User ID is valid.
Enter the Keypad Access User ID again for verification. The lock responds
with two beeps/flashes of the green LED. The lock responds with two beeps/
flashes of the red LED if the User ID was unconfirmed, or if the User ID was
already in use, or no space was found in the Keypad Access User Table.
Enter a one-digit value to select the access schedule for the User ID. The
value must be in the range of 0–6 where 0 indicates no access time restric-
tion. The lock responds with four beeps/flashes of the green LED if the
access schedule designation is valid. The lock responds with two
beeps/flashes of the red LED to indicate an error. Refer to the "Access
Schedules" section on page 8 for more detailed information.
The Keypad Access User is now added to the lock with the entered User ID
and a default PIN of all 0's if PIN length is not 0.
If additional Keypad Access Users are to be added, repeat Steps 4-6 until all
User IDs have been added. If no additional Keypad Access Users are to be
added, go to Step 8.
Press
(Enter key) to exit this procedure. The lock responds with two
simultaneous beeps/flashes of the green and red LEDs and exits this
procedure.
(Enter key) followed by the 2 key.
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerlever 4550