8.4 Remote Printer Reset

8.4.1

Reset in Serial Mode

It is possible to generate a software printer reset in serial mode. The [ENQ] <10> command will request
that the printer reset. (This is not a hardware reset). It will, however, completely initialize the hardware and
software but will not recover from a loss of software control.
Note: If the printer mode was changed by the [ESC] y <2> or <3> command, a soft reset will not return to
the power on default.
The command flow is as follows.
1.
The [ENQ] <10> will be acknowledged.
2.
During cleanup and initialization, the printer will be placed off-line.
3.
Before the printer initializes, it will try to clean up its input buffer and other internal processes.
a.
If there is information in the print buffer, it will be printed before the printer resets.
b.
If during cleanup the printer is in or enters an error state (like slip-load failure), the error and input
buffer will be cleared, and the printer will initialize.
c.
If during cleanup, the printer is in or enters a waiting for operator action (like slip request mode),
the operator wait state and input buffer will be cleared, and the printer will initialize.
d.
If the cover is open and there is data that can be printed, the printer will wait for the cover to be
closed, print the data, and then initialize.
e.
If the printer is idle, it will initialize.
4.
The printer's software will be reinitialized. Most of the initial default configuration information will be
reloaded; however, several configurations will not be loaded.
a.
The top of form position will not be changed.
b.
The mode (IBM/EPOS) will not be reset. Note: if the printer is in EPOS mode but was configured
for IBM with a font pitch that is not a normal EPOS font, the printer will use the IBM font but stay
in EPOS mode.
5.
The power-cycled flag will be set.
6.
The print head will be homed and recalibrated.
7.
Because the reset command can clear an error state, it is possible for a form to be in the printer after
initialization. If a form is detected, the printer will initialize with the form unclamped. The operator
should remove it before any data is sent to the printer. The default mode for the printer is receipt mode.
If data is sent to the printer without doing a station select, the printer will close the clamp and start to
print without generating an error. Receipt mode should not be assumed after reset.
8.
The printer will then go back on-line.
8.4.2

Reset in Parallel Mode

In parallel mode, driving the INIT signal on the parallel port for 100 milliseconds will generate a software
reset. It takes about two seconds for the printer to recover from a reset. The [ENQ] <10> command will
have the same effect, but it will not be acknowledged.