TransAct Ithaca 90PLUS Series Programmer's Manual page 81

Receipt/validation/journal printers pcos series
Hide thumbs Also See for Ithaca 90PLUS Series:
Table of Contents

Advertisement

Programmer's Guide
Function
ASCII
Hexadecimal
Decimal
IPCL
IPCL
EPOS
Description
Note
11/07/05
PcOS Series 90PLUS
Enable or disable dual station operation
[ESC] l <n>
1BH 6CH <n>
<27> <108> <n>
&%SD (enable dual station)
&%SS (enable single station)
none
The [ESC] l <n> command enables or disables dual station mode. If n = 1, dual
station mode is enabled. In dual station mode, both the receipt and
validation/slip paper feed drive will operate allowing the journal to record the
information printed on the inserted form. If n = 0, the printer will revert back to
single station operation. The effect of this command is to enable receipt feed in
slip or validation modes.
Any station select command will disable dual station mode.
Rev Q
Printer Control Codes
Station Control
Page 69