Printer Control Codes

EPOS Codes

5.17 EPOS Codes
This section lists the EPOS codes that are supported by the Series 90PLUS Printer. Ithaca Peripherals has no
control over of how Epson extends or changes these control codes. Ithaca Peripherals makes no guarantees as to
the operation of our printer when it replaces an Epson printer. The EPOS emulation is intended to make it as
easy as possible to replace an Epson printer with an Ithaca Series 90PLUS Printer.
The following section lists all EPOS commands that are processed. They are as close as possible to Epson
printers. The user must remember that the Series 90PLUS Printer is not designed as a drop-in replacement for an
Epson printer. The Ithaca Peripherals' Series 90PLUS Printer is designed to bring new and unique features and
functionalities to a POS receipt/validation printer.
5.17.1

Real-time Status

The Series 90PLUS Printer is available in serial and parallel versions. When Epson supports parallel
operation, the company redefines some of the standard IEEE 1284 interface signals to be special status
lines. The Series 90PLUS Printer does not alter the IEEE 1284 standard. If an application requires real-time
status from the printer, the IEEE 1284 bidirectional protocol must be used.
The Series 90PLUS Printer supports real-time status. The EPOS real-time status commands [DLE] [ENQ]
and [DLE] [EOT] are processed by the printer. The printer, however, does not support all the response bit
fields. See the descriptions below.
5.17.2

EPOS Command Summary

Please refer to the Epson ESC/POS Information Manual for field definitions.
The following is a list of the EPOS commands that are supported:
Command
[LF]
[FF]
[HT]
[BS]
[CR]
[DEL] [EOT] <n>
[DEL] [ENQ] <n>
[CAN]
[ESC] SI
[ESC][SP] <n>
[ESC] ! <n>
[ESC] $ <n
> <n
l
h
[ESC] % <n>
[ESC] & ...
[ESC] * <m> <n
1
[ESC] - <n>
Page 92
PcOS Series 90PLUS
Description
Feed line.
Eject form.
Set horizontal tab.
Return carriage.
Request real-time status.
Set real-time command.
Cancel print.
Set 24 cpi.
Set right-side character spacing.
Select print modes.
>
Set absolute print position.
> <n
>
Select single-density bit image mode.
2
Turn underline mode ON/OFF.
Rev Q
Programmer's Guide
Comment
Extension
Extension
Not the same
Not the same
Not the same
Extension
Not implemented
Not implemented
Extended
11/07/05