TransAct Ithaca 90PLUS Series Programmer's Manual page 37

Receipt/validation/journal printers pcos series
Hide thumbs Also See for Ithaca 90PLUS Series:
Table of Contents

Advertisement

Programmer's Guide
Function
ASCII
Hexadecimal
Decimal
IPCL
EPOS
Description
Function
ASCII
Hexadecimal
Decimal
IPCL
EPOS
Description
Function
ASCII
Hexadecimal
Decimal
IPCL
EPOS
Description
Function
ASCII
Hexadecimal
Decimal
IPCL
EPOS
Description
Function
ASCII
Hexadecimal
Decimal
IPCL
EPOS
Description
Notes
11/07/05
PcOS Series 90PLUS
Set form length in lines
[ESC] C <n>
1BH 43H <n>
<27> <67> <n>
&%SL<m
> <m
>
1
2
[ESC] C <n>
The [ESC] C <n> command sets the form length to <n> lines at the current line
spacing.
Set form length in inches
[ESC] C [NUL] <n>
1BH 43H <0> <n>
<27> <67> <0> <n>
&%SI <m
> <m
>
1
2
none
The [ESC] C [NUL] <n> command sets the form length to <n> inches.
Begin automatic line feed
[ESC] 5 <01>
1BH 35H 01H
<27> <53> <01>
&%MA
none
The [ESC] 5 <01> command sets automatic line feed mode which overrides the
configuration setting.
End automatic line feed
[ESC] 5 <0>
1BH 35H 00H
<27> <53> <0>
&%CA
none
The [ESC] 5 <0> command ends automatic line feed mode which overrides the
configuration setting.
Reverse line feed
[ESC] ]
1BH 5DH
<27> <93>
&%LR
none
The [ESC] ] command performs a reverse line feed at the current line spacing.
1.
The receipt station can tolerate no more than
2.
In validation mode, the form cannot be reversed past the first line of validation.
3.
In slip mode, the form should not be reversed past the first line of the slip.
Rev Q
Printer Control Codes
Vertical Motion
inch of reverse feed.
1/2