Programmer's Guide
Function
ASCII
Hexadecimal
Decimal
IPCL
EPOS
Description
Notes
EPOS note
11/07/05
PcOS Series 90PLUS
Control Feature Commands
[ESC] y <n>
1BH 79H <n>
<27> <121> <n>
&%Y0 through 9 or &%YX <m
[ESC] y <n>
Where n:
0
1
2
3
4
5
6
7
8
11
12
128+
10000001
10000010
10000100
10001000
10010000
10100000
11000000
The [ESC] y <n> command enables and disables command set features.
It is possible that the IPCL commands will interfere with the print data. If this is the
case, they can be disabled with an [ESC] y <4>.
1.
Quiet mode operation prints by making two passes for every pass in normal
mode. It generates less noise because only half the print wires are activated in
each pass. Quiet mode is slow and should only be used if quiet operation is
necessary.
2.
ESC y <2> and <3> allow the printer to be switched between normal and EPOS
modes. When the switch takes place, the current print buffer is printed, and the
printer reinitializes. These commands do not permanently change the
configuration. A power on reset will restore the mode that was configured in
menu mode. A reset by command or from the INIT pin will not restore the mode.
3.
ESC y <6> and <7> enable and disable the inquire processing. These commands
are not processed as they are received, but are buffered and then processed.
Because of this, [ENQ] commands sent after a disable may be answered. In
addition, [ENQ]'s sent after an enable may not be answered.
4.
The printer has a resident OCR-MA font that only works in utility mode and
contains Group 2 characters. They are defined and mapped per ANSI X3.111-
1986. Once mapped into a code page, they can be removed by issuing an [ESC]
y <12> command or a code page select command.
The [ESC] y command is active in EPOS mode; however, Modes 5 and 6 are
disabled.
Rev Q
Printer Control Codes
> <m
> <m
> (for numbers greater than 9)
1
2
3
Disables quiet mode operation
Enables quiet mode operation
Reinitializes the printer and forces IBM mode
Reinitializes the printer and forces EPOS mode
Disables IPCL commands
Enables IPCL commands (Note: Once disabled, the
command will not be a valid IPCL code).
Disables ENQ processing
Enables ENQ processing
Enables extended diagnostics
Overlays the current character chart with Group 2 OCR
MA characters
Replaces the OCR characters with the normal characters
Sets Windows control flags
Disables the next eject command, which allows Windows
drivers to do station select commands with paper source
selections. This is reset after it is used.
Disables the next knife cut command
Flags a MICR operation from Windows
Not defined
Causes the next slip select to ignore the form sensors
Causes the next receipt select to ignore the form sensors
when in receipt mode
Not defined
Miscellaneous Controls
Page 77