PRO165SL/SLE
4.3. Motor Mounting
DANGER: Electrical Shock Hazard!
Do not connect or disconnect electrical components, wires, and cables while this
l
product is connected to a power source.
Before you do maintenance to the equipment, disconnect the electrical power.
l
Uncouple or otherwise prevent motion of motor-coupled machinery when you do ser-
l
vice to the equipment.
Table 4-1:
Hardware Requirements
Stage
PRO165SL/SLE
(GEN 1)
PRO165SL/SLE
(GEN 2)
IMPORTANT: Use Loctite 242 or Loctite 248 on the motor and coupling adapter
hardware
be sure that the expiration date is legible and the product has not expired.
If your stage is used in a vacuum or cleanroom environment, contact Aerotech.
Figure 4-4:
Motor Mounting Overview
54
Shaft
Motor
Coupling
Screw Size
Screw Size
M4
M2.5
M4
M2.5
(Figure
4-4). Loctite products are printed with an expiration date. Before use,
Coupling
Coupling
Screw Bit Size
Screw Torque
T8 Torx
7 in·lbs
2 mm Hex
7 in·lbs
Hardware Manual
Special Coupling
Hardware
MIH01258
N/A
www.aerotech.com