Conductivity Trend - Pentair E-Box MAESTRO Installation And Operation Manual

Table of Contents

Advertisement

Installation and Operation Guide Version E-Box MAESTRO - Programming
CAUTION
pH too high or too low!
Skin irritation
ü Ensure that:
ü the cylinder has been removed from the pH probe (see Installation of probes
[
Page 43])
ü the pH probe was calibrated less than 6  months ago (see Calibration mode
[
Page 85])
ü pH probe is not clogged (see Cleaning the pH or RedOx probe [
• manual regulation: put the product "pH-" or "pH+" according to the pH drift.
• automatic regulation: check the proper functioning of the equipment.
If the pH value is Hi or Lo, check that an air bubble at the bottom of the pH probe does not distort
the measurement. Shake the device (like a mercury thermometer) so that, by centrifugal force,
any air bubble rises.
5.2.4

Conductivity Trend

1.
Conductivity trend
(updated every 2 hours)
2.
Conductivity has reached
alarm value
3.
Value of measured
conductivity
78 / 110
1
conductivity rises
conductivity is stable
conductivity decreases
value
(factory pre-set at 50  μS, can be changed on the alarm
menu, see Alarm mode [
value
(factory pre-set at 1200 μS, can be changed on the alarm
menu, see Alarm mode [
• display limited between 0 and 1999
• value out of display limit:
2
3
4
5
the conductivity has reached the maximum alarm
the conductivity has reached the minimum alarm
Conductivity < 0 g/l
Conductivity > 19.99 g/l
Ref. SB-CU-IMP-062EBA / A - 11.05.2023
Page 96])
Page 81])
Page 81])

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sb-pf-ens-002e

Table of Contents