2.1.3. Transformer Options

You can connect an external isolation transformer to the Motor Supply AC Input to reduce the
operating voltage of the motor. Using a transformer can also reduce electrical noise.
Table 2-5:
Nominal Motor Operating Voltages / Required AC Voltages 
Table 2-6:
Transformer Options
Transformer
TV0.3-28-56-ST
TM3
TM5
TV0.3-28
TV0.3-56
TV1.5, TV2.5, or TV5
www.aerotech.com
AC Voltage
28
56
115
230
Description
Generate 28 or 56 VAC from 115 VAC or 230 VAC input source voltage.
When rectified by the drive, it produces a 40 or 80 VDC power bus.
Power up to 4 drives, providing 300 watts of power
Power up to 4 drives providing 500 watts of power
Generate 28 VAC from 115 VAC or 230 VAC input source voltage. When
rectified by the drive, it produces a 40 VDC power bus.
Generate 56 VAC from 115 VAC or 230 VAC input source voltage. When
rectified by the drive, it produces an 80 VDC power bus.
1.5 kVA, 2.5 kVA, or 5 kVA isolation transformer; 115/230 VAC input; 28, 43,
56, 70, 115 VAC output
iXC4e/XC4e
DC Voltage
40
80
160
320