2.3.4. Encoder Fault Input

The encoder fault input is for use with encoders that have a fault output. This is provided by some
manufacturers and indicates a loss of encoder function. The active state of this input is parameter
configurable and the controller should be configured to disable the axis when the fault level is active.
The nominal trip voltage of the encoder fault input is +2.5 V.
Table 2-21:
Encoder Fault Input Pin on the Feedback Connector
Pin #
Description
23
Encoder Fault Input
Figure 2-28:
Encoder Fault Input Schematic (Feedback Connector)
www.aerotech.com
iXC4e/XC4e
In/Out/Bi
Input