Epson G Series Maintenance Manual page 49

Hide thumbs Also See for G Series:
Table of Contents

Advertisement

M/C Cable
(1) Turn OFF the Controller.
Removal
(2) Disconnect the power cable and signal cable connectors from the controller.
(3) Remove the Connector Sub Plate.
NOTE
Do not pull the Sub plate forcibly.
The M/C cables are still attached to the plate.
(4) Disconnect the connectors.
NOTE
Each connector has a unique number.
Each connector has a different shape.
NOTE
Do not disconect the buttary connector
connected with the battery board.
Otherwise, the calibration must be
executed.
M/C Cable
(1) Connect new M/C cable connectors to those of the Cable Unit.
Installation
(Connect to the connectors of the Cable Unit with the same number.)
(2) Mount the Connector Sub Plate.
(3) Connect the power cable and signal cable connectors to the controller.
(4) Turn ON the Controller.
(5) If the connector falls off from the battery, execute the calibration for All Joint.
G series Maintenance Rev.3
For details, refer to 3.3 Connector Sub Plate.
Connector: x10, x20, x30, x111, x121, X131
For details, refer to 3.3 Connector SubPlate.
For details, refer to 13 Calibration.
G1 Maintenance 4. Cable
M/C Cable