G3 Maintenance 14. Calibration
(2) Confirm the warning message and click the <Yes> button.
(3) Move the joint to calibrate manually to approximate 0 pulse position, as shown in the
194
dialog. After moving the joint click the <Next> button.
G series Maintenance Rev.3