14.2 Calibration Procedure

EPSON RC+ has a wizard for calibration.
This section indicates the calibration using the calibration wizard of EPSON RC+.
The same calibration procedure is used for each joint.
The steps below are calibration using Joint #1. Follow the steps below to calibrate other
joints.
When coordinates for the Manipulator working point require calculation, it is important for
Joint #2 to be calibrated accurately. Execute the procedure in "Calibration Using Right /
Left Arm Orientations" to accurately calibrate Joint #2. For details, refer to 14.3 Accurate
Calibration of Joint #2.
When calibrating Joint #4, you must calibrate Joint #3 and #4 at the same time. You cannot
calibrate Joint #4 alone because of the structure of the Manipulator.
If Err9716 or 5016 (Power supply failure of the absolute encoder. Replace the battery.
NOTE
Check the robot internal wiring) occurs, apply the procedure of 14.4 Calibration Procedure
without using Calibration Wizard - 3. Encoder Initialization and then, start the calibration
wizard.
The reference point (a point to check the accuracy) needs to be specified for calibration.
(1) Start the calibration wizard.
NOTE
iii. Select the joint and click the <Calibrate...> button.
G series Maintenance Rev.3
i. Select EPSON RC+ menu-[Setup]-[System Configuration].
ii. Select the [Robot]-[Robot**]-[Calibration].
Only selected robot can be calibrated.
G3 Maintenance 14. Calibration
193