9. Bellows

The bellows are provided in a unit of two pieces. The shape varies between the upper and
NOTE
lower bellows.
A large amount of dust is emitted when replacing the bellows.
Take the Manipulator to an outer room such as the room in front of the clean room's entrance,
or take the necessary countermeasures to prevent dust emission before removing the bellows.
Maintenance
Bellows
parts
Tools
Cross-point screwdriver
Bellows
(1) Remove the end effector.
Removal
(2) Remove the wires and tubes from the end effector.
(3) Turn ON the controller. Stop motor excitation. (MOTOR OFF)
(4) Loosen the two clamp bands on each bellows.
(5) Pull the bellows, rubber sheet, and clamp bands
G series Maintenance Rev.3
Name
out of the shaft.
(The rubber sheet is not used for the upper
bellows.)
G10 G20 Maintenance 9. Bellows
Quantity
150 mm
1
390 mm
1
Note
1497641
1499591
For clamp band removal
Clamp band (small)
Bellows
Clamp band (medium)
without rubber sheet
Clamp band (large)
Clamp band (small)