Epson G Series Maintenance Manual page 204

Hide thumbs Also See for G Series:
Table of Contents

Advertisement

G3 Maintenance 12. Lithium Battery
NOTE
For the EPSON RC+ 7.0 Ver. 7.2.x or later (firmware Ver.7.2.x.x or later), the
recommended replacement time for the battery can be checked in the [Maintenance] dialog
box of the EPSON RC+ 7.0.
For details, refer to the following manual.
RC700 series Maintenance Manual 6. Alarm
The battery may run out if it passes the recommended replacement time.
If no warnings of voltage reduction occur, the calibration for all joints is not necessary.
You need to perform calibration if the position moves from the originals after replaced the
battery.
Always use the lithium battery and battery board designated by us.
(Refer to 15. Maintenance Parts List.)
Be careful of the battery polarity to connect it correctly.
Battery unit (Lithium battery)
Maintenance
parts
Battery board
Nippers
Tools
Hexagonal wrench (width across flats: 3 mm)
Material
Wire tie
186
Name
Quantity
1
2117879
1
2120180
1
For cutting wire tie
1
For M4 screw
2
For fixing battery unit (battery)
2
For fixing cable
G series Maintenance Rev.3
Note

Advertisement

Table of Contents
loading

Table of Contents