6.11
Specifications of the Industrial Ethernet protocols
6.11.1
Modbus TCP protocol
TCP port
Protocol
Network topology
IP configuration
Transmission speed
Data transport layer
Modbus function codes
Read/write register
Message mode
Input (Target to Originator)
Output (Originator to Target)
AI = Analogue Input, AO = Analogue Output, DI = Digital Input, DO = Digital Output, Target = Server,
Originator = Client.
36
502
Internet protocol, version 4 (IPv4)
• Tree
• Star
• Line (open daisy chain)
• Fixed IP
• BOOTP (Bootstrap Protocol)
• DHCP (Dynamic Host Configuration Protocol)
10 and 100 MBit/s
EtherNet II, IEEE 802.3
3, 4, 16, 23
Max. 125 read registers and 123 write registers per telegram
Server
• All diagnostics and errors informations are with the highest pri-
ority and can be read by a PLC (refer to the supplement related
to the digital communication for the Type 8619).
• AI / DI / AO / DO: value, status, unit
• Device and modules: status
• Functions: value, status, unit
• PVC: value, status, unit
20 Process Variables Network (PVN)
English
Type 8619
Technical data