InView Display Communication Protocol Functions and Descriptions
InView Message Format used within Modbus ASCII Protocol
Response for Requesting Variable Data
BYTE
FUNC
COUNT
03
006
DATA OUTPUT
REG L.O. 0068
01
Change the InView Display Address
This function allows the ability to change the serial address in a display. For
example, change display address 001 to address 020. When doing this, you need
to know the address of the display you want to change. This is typically done
using the automation software. The following is an example of changing a
display (with the address of 005) to address 004.
Transmission is as follows:
Transmission for Changing the Serial Address
H.O
L.O
FUNC
ADDR
ADDR
01
00
See InView Display Communication Protocol Functions and Descriptions
for further explanation of the InView sign protocol being used.
Response: NONE
The InView display communication protocol that is used in conjunction with the
Modbus ASCII protocol is mostly limited due to the number of functions and
features that required by the InView products. This Protocol can be used for
downloading new messages of alphanumeric messages from an Allen-Bradley
controller.
Information that is used within the InView message is formatted differently than
that of the standard protocol. The following table shows the basic message
structure with a brief explanation of each part.
Chapter 4: InView Protocol
DATA
DATA
OUTPUT
OUTPUT
REG
REG L.O.
H.O. 0002
0002
00
2C
LRC Error
77
DATA
64
^AZ05^BE704^D
DATA
DATA OUTPUT
OUTPUT
REG H.O.
REG L.O. 0003
0003
00
Ready to
EOF
rec.
response
CR
LF
Ready to rec.
EOF
response
CR
User's Manual 0300277-03 Rev. A
4-31
3F
LF