2-14
Chapter 2: InView System Connectivity
User's Manual 0300277-02 Rev. C
However, upon successfully setting up the Gateway Address and Subnet Mask,
the following message appears telling you to cycle power to the module:
After the IP Address, Gateway Address, and Subnet Mask have all been
established, click the OK button on the bottom of the Ethernet TCP/IP
Communications window. This allows the settings to be saved and configuration
is now complete.
Once the settings have been saved, they can now be viewed by clicking on the
Advanced button located in the section titled TCP/IP settings on the Edit
Display window
Create the Message File
A background message of Rockwell Automation is automatically created. This is
also indicated by the letter B in the message list below the message creation box.
Message number 1 is highlighted and ready for creation. Create a message by
typing in the message box. Attributes for the messages can be changed or added
using the pull down menus located above the message creation box or from the
toolbar. Once message number 1 has been created, select the down arrow or type
2 in the box and select the Goto button. This allows message number 2 to be
created.
There is a size displayed in the lower right of the window. This is the size of the
message that is being created. This number starts from 11 and increases to a
maximum number that is determined by setting the partition size in software.
This is based on a total of 200,000 bytes. The smaller the partition size the more
messages are available. The limits are 450 bytes per message, 444 messages
minimum to 50 bytes per message, 4000 messages maximum. To change the
partition size, select File, followed by Partition.
See the following sections for more information regarding the message attributes.