Appendix B: Installing InView Marquee 2706-P4xC2-SC Message Displays B-7
Phillips
screws for
rear power
access
panel cover
4. The InView Display power terminal block is rated for wire ranges of 20
to 6 AWG for the power wiring. Two trade holes are provided for wiring
(on rear and underneath of display). Choose the appropriate entry point
for your installation location. If you choose to use the trade hole
underneath the display, make sure you transfer the watertight hole plug
and re-install it in the rear trade hole. Pull the electrical wires through the
trade hole. Ensure you follow all applicable, local, electrical codes for
completion of the wiring.
5. Wire the external power to the rear access power panel as shown. Strip
the electrical wires back 6.35 mm (0.25 in), or as needed. Insert the wires
into the appropriate terminal connection using the image and table
provided.
6. Tighten the screws to a maximum of 0.79 N-m (7 in-lbs):
Wire
Color
Black
White
Green
7. In order to comply with Part 15 of FCC Rules, attach one of the provided
ferrites around the incoming power wiring. Secure with one of the
provided tie wraps to the tie wrap anchor.
8. Replace the rear access power panel by inserting the 4 8-32 Phillips
screws. Tighten to a maximum of 1.13 N-m (10.00 in-lbs).
Wiring Communications to the Displays
Wire the Comms module power and communications into the displays as
follows:
1. Remove the 4, 8-32 Phillips screws holding the rear communication
access panel. Retain the screws in a safe place.
Rear trade
hole
Wire Name
Line (Hot) connect to L
Neutral connect to N
Ground connect to G
User's Manual 0300277-03 Rev. A
Need help?
Do you have a question about the Spectrum Controls 2706-P22-SC and is the answer not in the manual?