Allied Motion Spectrum Controls 2706-P22-SC User Manual page 87

Inview message displays
Table of Contents

Advertisement

NOTE
NOTE
Transmission for Downloading Message 1 (Example 2)
Beg of
ADDR
FUNC
Frame
:
FF
01
NOTE
Transmission for Downloading Message 2 (Example 2)
Beg of
ADDR
FUNC
Frame
:
FF
01
NOTE
See InView Display Communication Protocol Functions and Descriptions
for further explanation of the InView sign protocol being used.
Response: NONE
2000 ms pause
1. Download two messages.
This step is accomplished with two separate transmissions to the display,
one for each message.
Transmission is as follows:
The total number of bytes for each transmission (from the beginning of
frame to ready to rec. resp.) must not exceed 500 bytes.
Download message file #0001
H.O
L.O
ADDR
ADDR
00
64
See InView Display Communication Protocol Functions and Descriptions
for further explanation of the InView sign protocol being used.
Response: NONE
300 ms pause
Download message file #0002
H.O
L.O
ADDR
ADDR
00
64
See InView Display Communication Protocol Functions and Descriptions
for further explanation of the InView sign protocol being used.
Chapter 4: InView Protocol
DATA
^AZ00^BA2001^["b^I^^1^\1Hello^D
DATA
^AZ00^BA1002^[b^I^^1^\2Part count
=
^]A0^]B0^P00^D
User's Manual 0300277-03 Rev. A
4-25
Ready
to rec.
EOF
response
CR
LF
Ready
EOF
to rec.
response
CR
LF