d) SR193 clamp
Nominal range
Measurement range
Maximum clamping diameter
Influence of the conductor's
position in the clamp
Influence of an adjacent
conductor carrying an AC current
Safety
NOTE: Currents < 0.5 A are set to zero.
e) MN93 clamp
Nominal range
Measurement range
Maximum clamping diameter
Influence of the conductor's position in
the clamp
Influence of an adjacent conductor
carrying an AC current
Safety
NOTE: Currents < 0.1 A are set to zero.
52
SR193 clamp
0.5 A to 1200 Aac (I >1000 A for 5 minutes maximum)
IEC/EN 61010-2-032 or BS EN 61010-2-032, pollution
degree 2, 600 V CAT IV, 1000 V CAT III
Table 8
MN93 clamp
0.5 A to 240 Aac max (I >200 A non-continuous)
IEC/EN 61010-2-032 or BS EN 61010-2-032,
pollution degree 2, 300 V CAT IV, 600 V CAT III
Table 9
Power & Energy Logger Model PEL 52 - User Manual
1000 Aac
2.04 in (52 mm)
< 0.1 % from DC to 440 Hz
> 40 dB typical at 50/60 Hz
200 Aac for f ≤1 k Hz
.78 in (20 mm)
< 0.5 %, at 50/60 Hz
> 35 dB typical at 50/60 Hz

Advertisement