4. Replacement and Adjustment
• Attach the gear with the face of the gear [A] inserted against the frame so that it can fit over
the flat side of the shaft [B].
9.
Lower the left side of the scanner unit.
10.
Raise the right side of the scanner unit (p.264).
11.
On the right, remove the ground plate [A] from the shaft. (
• Conductive grease is applied to the shaft and ground plate. Avoid to attach it around.
296
x1)