6. Troubleshooting

SC600: Communication

SC632-00
SC633-00
SC634-00
690
B
Counter device error 1
After 3 attempts to send a data frame to the optional counter device via the
serial communication line, no ACK signal was received within 100 ms.
• Serial line between the optional counter device, the relay board and
copier control board is disconnected or damaged.
• Make sure that SP5113 is set to enable the optional counter device.
• Check if the setting of the SP5113 is correctly set.
• Check the connection between the main machine and optional counter
device.
B
Counter device error 2
After communication was established, the controller receivee the brake signal
from the accounting device.
• Serial line between the optional counter device, the relay board and
copier control board is disconnected or damaged.
• Make sure that SP5113 is set to enable the optional counter device.
• Confirm that the setting of SP5113 is correct.
• Check the connection between the main machine and optional counter
device.
B
Counter device error 3
A backup RAM error was returned by the counter device.
• Counter device control board defective
• Backup battery of counter device defective
• Replace the counter device.
CTL
CTL
CTL