4. Replacement and Adjustment
6.
Disconnect all the connectors from CN258 [A], CN259 [B], CN256 [C], and CN257 [D] on
IOB and CN216 [E] and cn215 [F] on BiCU

Separating the Main Unit from the Scanner Unit

Separate the main unit from the scanner unit completely.
1.
Disconnect the scanner unit from the bracket [A] [B] (
2.
Slowly, pull the scanner stand away from the back of the main unit.
• To avoid scratching or breaking the original table, never lay anything on the original table
while you are working.
278