4. Replacement and Adjustment
6.
Remove the screw on the left side [A] and the leaf spring [B] on the left of the exposure
glass. (
x1 with washer)
7.
Remove the exposure glass.

Precaution

When you reinstall the exposure glass, set the glass so that the blue dot on the side of the glass is placed
at the front side of the main unit.