HPE ProLiant DL160 Gen10 Maintenance And Service Manual page 52

Hide thumbs Also See for ProLiant DL160 Gen10:
Table of Contents

Advertisement

Removing and replacing a Flexible Slot power supply
Removing and replacing a Flexible Slot power supply
Prerequisites
Prerequisites
Before replacing a power supply, review the following:
Power supply warnings and cautions
DC power supply warnings and cautions
If you are replacing a DC power supply, make sure that you have a Phillips No.1 screwdriver available.
About this task
About this task
WARNING:
WARNING: To reduce the risk of personal injury from hot surfaces, allow the power supply or power supply blank to cool
before touching it.
CAUTION:
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with
either a component or a blank.
Procedure
Procedure
1. If the server is using a single power supply only, remove all power from the server:
a. Back up all server data.
b. If installed, remove the front bezel .
c. Power down the server.
2. If installed, open the cable management arm .
3. Release the power cords, wires, and cables from the strain relief strap.
AC power supply
DC power supply
HPE ProLiant DL160 Gen10 Server Maintenance and Service Guide