1
Temperature range
Temperature range
Operating
Nonoperating
Relative humidity (noncondensing) —
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per 1000 ft) to 3048 m (10,000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit and rate of change
might be limited by the type and number of options installed.
Value
Value
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
Minimum to be the higher (more moisture) of -12°C (10.4°F) dew point or 8% relative humidity
Maximum to be 24°C (75.2°F) dew point or 90% relative humidity
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature