HPE ProLiant DL160 Gen10 Maintenance And Service Manual page 141

Hide thumbs Also See for ProLiant DL160 Gen10:
Table of Contents

Advertisement

Specification
Specification
Input requirements
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Maximum rated input power
BTUs per hour
Power supply output
Power supply output
Rated steady-state power
Maximum peak power
HPE 800 W Flex Slot Universal Hot-plug Low Halogen Power Supply
HPE
800 W Flex Slot Universal Hot-plug Low Halogen Power Supply
Value
Value
200 VAC to 240 VAC
240 VDC for China only
50 Hz to 60 Hz
Not applicable to 240 VDC
4.35 A at 200 VAC
3.62 A at 240 VAC
3.62 A at 240 VDC for China only
851 W at 200 VAC
848 W at 240 VAC
848 W at 240 VDC for China only
2905 at 200 VAC
2893 at 240 VAC
2893 at 240 VDC for China only
800 W at 200 VAC to 240 VAC input
800 W at 240 VDC input for China only
800 W at 200 VAC to 240 VAC input
800 W at 240 VDC input for China only
HPE ProLiant DL160 Gen10 Server Maintenance and Service Guide
141