Set Password - Quantum SNC 4500 User Manual

Quantum snc 4500: user guide
Hide thumbs Also See for SNC 4500:
Table of Contents

Advertisement

set MinOpTemp [temperature]
Contact ATAC before using this command.
CAUTION
The set MinOpTemp command sets the minimum internal operating temperature of the SNC in degrees
Celsius. If the internal temperature of the SNC falls below the minimum operating temperature, thermal
control event handling occurs. Valid values are from 0 to 15. The default setting is "0." Refer to
MinOpTemp
on page 71.This command must be followed by saveConfiguration restart.
Valid Temperature Values
0-15
Ready.
set minoptemp 5
Ready.*
set OpTempWarn [temperature]
Contact ATAC before using this command.
CAUTION
The set OpTempWarn command sets the number of degrees Celsius before a thermal control event warns
you if the SNC is approaching the minimum or maximum internal operating temperature. The warning is sent
to the system log. Valid values are from 0 to 15. The default setting is "5." Refer to
[temperature]. This command must be followed by saveConfiguration restart.
Temperature Valid Values
0-15
Ready.
set optempwarn 5
Ready.*

set Password

The restoreConfiguration default command sets the password to the default value "Password."
Passwords are case sensitive. They can be from 1 to 35 characters long, with no spaces. When the
password is empty, Telnet and FTP do not validate the password. To create an empty password, do not
type an answer to the password command confirmation prompts.
The following is an example of the input and output for the set Password command. Enter the old
password. In the example below, the old password is "Password." Type in the new password at the New
Password prompt. Re-enter the password at the Confirm New Password prompt. Neither entry displays
on the screen. This command must be followed by saveConfiguration norestart.
Ready.
set password
Old Password: Password
New Password:
Confirm New Password:
Your password has been changed.
Ready. *
SNC 450x User's Guide
get
set OpTempWarn
93

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snc 450xSnc 4501

Table of Contents