DisplayEventLog [ + | - | = | <ESC>] >> +
0132 10/07/2003 14:32:00 Voltage VCC Warning Level reached at 4.72 Volts
0133 10/07/2003 15:00:02 Rx Packet Error. Net #2
0134 10/08/2003 08:00:39 Bridge was booted/reset.
0135 10/08/2003 08:00:48 Unable to connect to an SNTP server
0136 10/08/2003 08:01:49 Voltage VCC Warning Level reached at 4.72 Volts
DisplayEventLog [ + | - | = | <ESC>] >>
Ready.
displayTraceLog <scroll>
Contact ATAC before using this command.
CAUTION
The DisplayTraceLog <+|-|=|<esc>> command displays the most recent page of trace log entries. Typing
a "+", "-" or "=" (no quotation marks) causes the next, previous or same page of trace log entries to be
displayed. No events are recorded until the command has been completed. Press ESC and Return to exit
the command and return to CLI. New entries begin. This command takes effect immediately.
Scroll
Meaning
+
Display the next page of trace log entries
-
Display the previous page of trace log entries
=
Display the same page of trace log entries
Ready.
displaytracelog
ADIC SNC
Trace Log W
0608 12/10/2003 11:25:22 Bus = 0 Target ID = 1
0609 12/10/2003 11:25:22 Bus = 0 Target ID = 1
0610 12/10/2003 11:25:22 Bus = 0 Target ID = 1
0611 12/10/2003 11:25:22 Bus = 0 Target ID = 1
SNC 450x User's Guide
CDB = 03 00 00 00 20 00 00 00 00 00
00 00 00 00 00 00
Stat= 02
Sense Data = 70 00 02 00 00 00 00 1c 00 00
00 00 3a 00 00 00 10 13
CDB = 1e 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00
Stat= 00
Sense Data = 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
CDB = 03 00 00 00 20 00 00 00 00 00
00 00 00 00 00 00
Stat= 02
Sense Data = 70 00 02 00 00 00 00 1c 00 00
00 00 3a 00 00 00 10 13
CDB = 4c 02 40 00 00 00 00 00 00 00
00 00 00 00 00 00
Stat= 00
Sense Data = 00 00 00 00 00 00 00 00 00 00
59