Serial Port
The RS-232 serial port is an RJ-11 connection used to connect this port to the serial port on a service
computer. The position of the RS-232 serial port on an SNC 4500 can be seen in
position of the RS-232 serial port on an SNC 4501 is shown in
To configure the management port IP address, you must use either the serial
Note
port or the library operator panel.
The serial port provides support for remote monitoring and management when you use a terminal session
to access the command line interface (CLI).
The serial port is configured at:
•
Baud rate: 115,200 bits per second
•
Data Bits: 8
•
Parity: None
•
Stop Bits: 1
•
Flow Control: None
•
Terminal type: ASCII
•
Echo: off
Operating Specifications
This section contains the physical, electrical, and environmental specifications for the SNC 4500 and SNC
4501.
SNC 4500 Dimensions
•
Depth: 33.02 cm (13 in.)
•
Height: 4.37 cm (1.72 in.)
•
Width: 48.26 cm (19 in.)
•
Weight: 4.53 kg (10 lbs.)
SNC 4501 Dimensions
•
Depth: 17.78 cm (7 in.)
•
Height: 7.62 cm (3 in.)
•
Width: 15.24 cm (6 in.)
•
Weight: 1.13 kg (2.5 lbs)
Operating Environment
The operating environment is as follows:
•
Operating temperature: 10° to 40°C (50° to 104°F) external
•
Blower and airflow: Be sure there is sufficient airflow to the rack or library.
SNC 450x User's Guide
Figure 8
Figure 9
on page 19.
on page 19. The
5