Ready.
exit
The exit command ends the current TCP/IP CLI session. It has no effect if used during a serial CLI session.
A Telnet session ends after 15 minutes of inactivity. No more than three Telnet sessions can be active at
one time. This command takes effect immediately.
firmwareRestart
The firmwareRestart command causes the SNC to reboot and then re-initialize its firmware. When the
firmware has finished rebooting, the Ready prompt is displayed. This command takes effect immediately.
Uart is Initialized
DRAM
Data Line Test
SRAM
Data Line Test
BBRAM Data Line Test
DRAM
Address Line Test
SRAM
Address Line Test
BBRAM Address Line Test
DRAM
Pattern Test
DRAM
Pattern Test
DRAM
Pattern Test
DRAM
Pattern Test
SRAM
Pattern Test
SRAM
Pattern Test
SRAM
Pattern Test
SRAM
Pattern Test
BBRAM Pattern Test
BBRAM Pattern Test
BBRAM Pattern Test
BBRAM Pattern Test
DRAM
Swap Pattern Test1
DRAM
Swap Pattern Test2
DRAM
Swap Pattern Test3
DRAM
Swap Pattern Test4
***** Memory Tests Complete *****
Memory Clear
EPLD Version 0 Detected
DS1629_DVC_TYPE initialized
ADIC SNC 450x
(c) 2003 ATTO Technology, Incorporated.
62
00 00 00 00 00 00
Stat= 00
Sense Data = 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
Passed
Passed
Passed
Passed
Passed
Passed
1
Passed
2
Passed
3
Passed
4
Passed
1
Passed
2
Passed
3
Passed
4
Passed
1
Passed
2
Passed
3
Passed
4
Passed
Passed
Passed
Passed
Passed
Finished
Management Port Command Reference