Fill in appropriate values for the data ports IP addresses, gateways, and subnet masks.
CAUTION
4
Click Submit.
5
Click the Restart button in the side bar. Then click Restart.
CAUTION
6
Wait for the reboot to be completed. Then, verify that the SNC can be accessed on the local Ethernet
network by issuing the ping command from a service computer on the SNC network to the SNC mp0,
dp0, and dp1.
28
Consult your service representative before changing the Ethernet
speed values or the MTU (Maximum Transmission Unit) values.
If the host and SNC are on different subnets, ping may return
"Destination Net Unreachable." Check with your network
administrator to determine if pings across subnets have been
disabled for security reasons. If so, you will need to perform the ping
from a host on the same subnet as the SNC or rely on the host's iSCSI
initiator to enumerate the SNC data ports.