get iSNSServer
Contact ATAC before using this command.
CAUTION
The get iSNSServer specifies the IP address of a valid iSNS server the SNC uses to discover iSCSI
initiators. Refer to
set iSNSServer [IP address]
Ready.
get isnsserver
iSNSServer = 0.0.0.0
Ready.
get MaxOpTemp
Contact ATAC before using this command.
CAUTION
The get MaxOpTemp command displays the maximum internal operating temperature of the SNC in
degrees Celsius. Valid values are from 55 to 70. Refer to
Ready.
get maxoptemp
MaxOpTemp = 70 C
Ready.
get MinOpTemp
Contact ATAC before using this command.
CAUTION
The get MinOpTemp command sets the minimum internal operating temperature of the SNC in degrees
Celsius. Valid values are from 0 to 15. The default setting is "0." Refer to
Ready.
get minoptemp
MinOpTemp = 0 C
Ready.
get OpTempWarn
Contact ATAC before using this command.
CAUTION
The get OpTempWarn command displays the number of degrees Celsius before a thermal control event
warns you if the SNC is approaching the minimum or maximum internal operating temperature. The warning
is sent to the system log. Valid values are from 0 to 15. Refer to
Ready.
get optempwarn
OpTempWarn = 5 C
Ready.
SNC 450x User's Guide
on page 92.
set MaxOpTemp
set OpTempWarn
[temperature].
set MinOpTemp
[temperature].
[temperature].
71