Ready.
set serialportbaudrate 57600
Ready.*
set SerialPortEcho [status]
The set SerialPortEcho command enables or disables repetition of keyboard input on the screen. When
enabled, all non-control character keyboard input is output to the display. Set the local ASCII terminal (or
terminal emulator) echo settings to disabled if using set SerialPortEcho enabled. The default setting is
"enabled." Refer to
get SerialPortEcho
restart.
Status
Meaning
enabled
Keyboard input is repeated on the display
disabled
Keyboard input is not repeated on the display
Ready.
set serialportecho disabled
Ready. *
set SNTP [status]
The set SNTP command controls the NTP (Network Time Protocol) settings for the SNC. When enabled,
the SNC tries to contact a specified NTP server at reset and every 12 hours after to initialize or synchronize
the time. The default setting is "enabled." Refer to
by saveConfiguration restart.
Status
Meaning
enabled
The SNC tries to contact the specified NTP server
disabled
The SNC does not try to contact an NTP server
Ready.
set sntp enabled
Ready.*
set SNTPServer [IP address]
The set SNTPServer command controls the IP address of the NTP time server that the SNC contacts to
initialize or synchronize the time. When enabled, the SNC contacts the specified NTP time server at reset
and every 12 hours thereafter. If you want contact with the NTP time server before 12 hours, issue a
firmwareRestart command. Refer to
If the SNC is unable to contact the specified NTP server within 30 seconds, the SNC tries to contact the first
auxiliary NTP time server. If the first auxiliary NTP time server is not available, the SNC tries to contact the
second auxiliary NTP time server. If the second auxiliary NTP time server is not available, the SNC
continues to approximate the time based on the most recent NTP time server, physical real time clock or
manual initialization or synchronization. Three time servers are provided in the SNC. This command must
be followed by saveConfiguration restart.
The default setting is "192.43.244.18" (www.time.nist.gov). Refer to
Possible IP Addresses
192.43.244.18
SNC 450x User's Guide
on page 74. This command must be followed by saveConfiguration
get SNTP
get SNTPServer
Meaning
time server at www.time.nist.gov
on page 74. This command must be followed
on page 74.
get SNTPServer
on page 74.