set iSNSLoginControl [status]
Contact ATAC before using this command.
CAUTION
The set iSNSLoginControl command specifies whether or not the SNC delegates its access control and
authorization to an iSNS server. The default setting is "disabled." Refer to
page 92 and
get iSNSLoginControl
Status
Meaning
enabled
The SNC delegates its access control and authorization to an iSNS server
disabled
The SNC retains its access control and authorization
Ready.
set isnslogincontrol disabled
Ready.*
set iSNSServer [IP address]
Contact ATAC before using this command.
CAUTION
The set iSNSServer specifies the IP address of a valid iSNS server from which the SNC attempts iSCSI
initiator discovery where xxx.xxx.xxx.xxx is the IP address. Setting to 0.0.0.0 disables iSNS server lookup.
The default setting is "0.0.0.0." A saveConfiguration restart command must be used to permanently save
this configuration. Refer to
saveConfiguration restart.
Ready.
set isnsserver 192.16.5.198
Ready.*
set MaxOpTemp [temperature]
Contact ATAC before using this command.
CAUTION
The set MaxOpTemp command sets the maximum internal operating temperature of the SNC in degrees
Celsius. If the internal temperature of the SNC rises above the maximum operating temperature, thermal
control event handling occurs. Valid values are from 55 to 70. The default setting is "70." Refer to
MaxOpTemp
on page 71. This command must be followed by saveConfiguration restart.
Valid Temperature Values
55-70
Ready.
set maxoptemp 60
Ready.*