Quantum DX100 Unpacking And Installation Instructions

Quantum dx100: install guide
Hide thumbs Also See for DX100:

Advertisement

Quick Links

Introduction
and Installation Instructions
Rack Space Requirements.........................................................................................5
Environmental Conditions .......................................................................................6
Providing Necessary Tools and Equipment ..........................................................7
Taking ESD Precautions ...........................................................................................7
Locating the Mounting Position ............................................................................12
Installing the DX-Series Storage Array.................................................................15
Installing the Fibre Channel Switch (DX100 Only).............................................20
Installing the Ethernet Switch (DX100 Only).......................................................25
Installing the DX-Series Controller .......................................................................27
Installing the AC Power Sequencers (DX100 Only) ...........................................30
Installing the SFP Connectors ................................................................................41
Verifying Storage Array Dip Switches .................................................................43
Cabling a DX30.........................................................................................................44
Cabling a DX100.......................................................................................................46
Quantum DX-Series
System Unpacking
3
4
7
7
12
41
41
1

Advertisement

Table of Contents
loading

Summary of Contents for Quantum DX100

  • Page 1: Table Of Contents

    Installing the DX-Series Storage Array...15 Installing the Fibre Channel Switch (DX100 Only)...20 Installing the Ethernet Switch (DX100 Only)...25 Installing the DX-Series Controller ...27 Installing the AC Power Sequencers (DX100 Only) ...30 Installing Additional Storage Arrays Cabling the DX-Series System Installing the SFP Connectors ...41 Verifying Storage Array Dip Switches ...43...
  • Page 2 Made in the USA. Quantum Corporation provides this publication “as is” without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Quantum Corporation may revise this publication from time to time without notice.
  • Page 3 • The system emulates an ATL P1000 library with up to 55 virtual digital linear tape (DLT™) 7000 tape drives for DX100 and up to 30 DLT7000 tape drives for DX30 (see Both the DX30 and the DX100 use the same system components (controller and storage arrays).
  • Page 4: Selecting An Installation Location

    Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 1 DX-Series Components DX-Series controller Ethernet switch (DX100 only) Fibre Channel switch (DX100 only) DX-Series storage array AC power sequencer (DX100 only) Selecting an Installation Location When choosing an installation site for the DX-Series system, consider the following requirements: •...
  • Page 5 DX30 base unit - 6U (15U with a maximum of 4 storage arrays) • DX100 base unit - 12U (58U for a maximum of 16 storage arrays, two Fibre Channel switches, two or more AC power sequencers, and one Ethernet switch) Weight - Storage array - 75 lbs (34 kg), controller - 52 lbs (24 kg) •...
  • Page 6: Environmental Conditions

    Humidity: 20%-80% non-condensing Temperature: 15°C-35°C (59°F-95°F) Altitude: -984 to 10,000 feet (-300 to 3048 meters) For additional DX-Series specifications (including environmental Note: requirements during shipping and storage), see the Quantum DX-Series User’s Guide (PN 6513501). Selecting an Installation Location...
  • Page 7: Preparing For The Installation

    This section explains how to unpack the DX-Series system components and move them to their final installation location. The DX-Series system is shipped in two configurations: DX30 and DX100 (see Quantum DX-Series System Unpacking and Installation Instructions Providing Necessary Tools and Equipment Taking ESD Precautions #1 PHILLIPS®...
  • Page 8 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Table 1 DX-Series Packaging Contents By following these instructions, you help ensure that the system will continue to be safeguarded after it arrives at the installation site. Unpack and remove the following components from the packing materials (see •...
  • Page 9 Figure 3 Unpacking the DX30 DX30 packaging Quantum DX-Series System Unpacking and Installation Instructions Storage array accessory kit packing foam Storage array Bottom packing foam Cover Hard drive sleds Controller accessory kit packing foam Controller Bottom packing foam Unpacking the DX-Series System...
  • Page 10 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 4 Unpacking the DX100 DX100 packaging Fibre Channel switch accessory kit Cover Fibre Channel switch Controller accessory kit packing foam Controller packing foam Unpacking the DX-Series System...
  • Page 11 Figure 5 Unpacking Additional Storage Array(s) Accessory kit: 2 power cords, Figure 6 Unpacking the 2 strain-relief brackets, and 2 Power Kit Ethernet cables Quantum DX-Series System Unpacking and Installation Instructions Storage array accessory kit packing foam Storage array Bottom packing foam...
  • Page 12: Installing The Dx-Series System

    Refer to Table 2 Rack Hole Types Locating the Mounting Position Installing the DX-Series Storage Array Installing the Fibre Channel Switch (DX100 Only) Installing the Ethernet Switch (DX100 Only) Installing the AC Power Sequencers (DX100 Only) Installing the DX-Series Controller figure 7).
  • Page 13 - used to secure the system components to the rack rails. Quantum DX-Series System Unpacking and Installation Instructions The rails within the rack have a hole pattern that repeats Note: throughout the rail. X marks the screw positions. Install nut clips (included in the accessory kit) on the rails if necessary.
  • Page 14: Back View

    Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 8 Mounting Locations Back View DX-Series controller (3U) Ethernet switch (1U DX100 only) Fibre Channel Switch (1U DX100 only) Storage arrays (8 shown, 3U each) Power sequencers...
  • Page 15 Storage Array • • Table 3 Storage Array Mounting Hardware Quantum DX-Series System Unpacking and Installation Instructions If this is an upgrade to an existing DX-Series system, see Note: Additional Storage Arrays Preparing the Storage Array for installation Installing the Storage Array...
  • Page 16 1 Install a spacer on each side with 6-32 x 10 flat head PHILLIPS screws provided in the storage array accessory kit (see Mounting spacer 1 Install the left and right storage array support brackets at the beginning of a hole pattern (see Locating the Mounting Position loosely install two 10-32 x .50 in.
  • Page 17 Figure 11 Storage Array Mounting Holes Storage array mounting holes Left rail shown Quantum DX-Series System Unpacking and Installation Instructions Right support bracket 2 With the support brackets installed, prepare the storage array mounting holes if necessary. Refer to table 2...
  • Page 18 Figure 12 Securing the Storage Array to the Rack 6 Secure the storage array to the rack with two 10-32 x 1.25 in. (M5 x 32 metric also provided) black PHILLIPS screws on each side of the front of the chassis. (see figure 12).
  • Page 19 Figure 13 Installing the Mounting Brackets Quantum DX-Series System Unpacking and Installation Instructions 8 Install each of the hard drive sleds into the DX-Series storage array chassis (see figure 14). The hard drives must be installed in the proper sequence since Note: RAID sets have already been established at the factory.
  • Page 20: Installing The Fibre Channel Switch (Dx100 Only)

    Drive sled 1 Locking screw Storage Array Drive Bay Numbering The DX-Series storage array is now installed in the rack. If this is a DX30 installation, continue with Installing the DX-Series Controller If this is a DX100 installation, continue with Switch (DX100 Only).
  • Page 21 Table 4 Fibre Channel Switch Mounting Hardware Quantum DX-Series System Unpacking and Installation Instructions Figure Description Mounting plates (used only with rack rails with through holes or threaded holes) Slotted screws PHILLIPS screws (only 8 used for front and back rack mounting)
  • Page 22 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 15 Assembling the Right and Left Support Brackets slotted screws Front mounting bracket Left support bracket shown back mounting bracket Second mounting hole 2 Remove the right and left slide rails from the support brackets.
  • Page 23 Rails Slotted screws Switch may be visually different Quantum DX-Series System Unpacking and Installation Instructions Fibre Channel switch 4 From the back of the rack, install the Fibre Channel switch support brackets with two PHILLIPS screws on each bracket in the front and in...
  • Page 24 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 17 Installing the Right and Left Support Brackets in the Rack Back of rack Screws Support brackets Screws 5 Slide the Fibre Channel switch into the support brackets in the back of the...
  • Page 25 To install the Ethernet switch: Installing the Ethernet Switch (DX100 Only) Quantum DX-Series System Unpacking and Installation Instructions Switch may be visually different Fibre Channel switch 6 Install 2U blank-off plate in front of rack covering the space taken by the Fibre Channel switch and Ethernet switch.
  • Page 26 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 19 Installing the Ethernet Mounting Ears Figure 20 Installing the Ethernet Switch into the Rack Ethernet switch PHILLIPS screws 2 Install the Ethernet switch into the back of the rack directly above the...
  • Page 27 Controller Rails Figure 22 Installing the Screws Controller Chassis Mounting Plates Quantum DX-Series System Unpacking and Installation Instructions 1 Each DX-Series controller rail is shipped in three pieces, six total for both rails (see figure 21). Mounting brackets (2 pieces)
  • Page 28 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 23 Assembling the Controller Rails Locking plate 3 Determine the depth of the rack (30 in, 76.2 cm minimum) and assemble each DX-Series controller rail with two PHILLIPS screws and locking plate at the appropriate depth (see 4 Install the DX-Series controller rails into the rack with four 10-32 x .50 in.
  • Page 29 Figure 24 Installing the DX-Series Controller Rails Left controller rail Quantum DX-Series System Unpacking and Installation Instructions Screws Right controller rail 5 Slide the DX-Series controller into the support brackets in the rack and secure with two black 10-32 x .75 in. PHILLIPS screws on each side of the...
  • Page 30: Installing The Ac Power Sequencers (Dx100 Only)

    Document 6513502-06 A01 October 2006 Figure 25 Installing the DX-Series Controller The DX100 storage arrays must be powered on in the correct order to avoid Installing the AC inrush current overflows. To achieve this, the power sequencers are installed Power Sequencers to automatically power on the storage arrays in the correct order.
  • Page 31 Daisy chain strapping In Daisy chain strapping Out Figure 27 Removing the Mounting Brackets Quantum DX-Series System Unpacking and Installation Instructions 2 Remove the three PHILLIPS screws securing the mounting brackets on each side of the power sequencer (see Screws...
  • Page 32 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 28 Installing the Hold Down Bracket Assembly Left mounting bracket Hold down bracket Cabling and Installing the AC Power Sequencer To simplify installation, the power cords for the AC power sequencer, controller, Ethernet switch, Fibre Channel switch, and storage arrays must be installed outside of the rack.
  • Page 33 Screws Figure 30 Installing the Cable Clamp and Power Cable Quantum DX-Series System Unpacking and Installation Instructions 2 Install the cable clamp on the power sequencer using two pan head PHILLIPS screws provided in the accessory kit (see Screws Cable clamp 3 Install the AC power cable through the cable clamp and into the AC power sequencer.
  • Page 34 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 31 Installing the AC Power Cable Figure 32 Connecting the First Power Connector Tie wrap Tension screw AC power cable 4 Connect the first power connector on the controller to outlet J1 on the first...
  • Page 35 Secondary AC Sequencer 8 10 If AC power sequencers five through eight are present in a second rack: Quantum DX-Series System Unpacking and Installation Instructions 6 Connect the following power cables for systems with two to sixteen storage arrays (see...
  • Page 36 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 33 DX100 Power Cabling (Controller, Ethernet and Fibre Channel Switch) Primary AC power source (separate circuit) AC input Secondary AC power source (separate circuit) AC input Connect strapping port strapping port on the sixth AC power sequencer.
  • Page 37 Third AC power sequencer AC input Secondary AC power source (separate circuit) AC input Fourth AC power sequencer Quantum DX-Series System Unpacking and Installation Instructions Storage array 1 Storage array 5 Installing the DX-Series System Document 6513502-06 A01 October 2006...
  • Page 38 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 36 Cabling Second Fibre Channel Switch Primary AC power source (separate circuit) AC input Secondary AC power source (separate circuit) AC input Fifth AC power sequencer Sixth AC power sequencer...
  • Page 39 Seventh AC power sequencer AC input Secondary AC power source (separate circuit) AC input Eighth AC power sequencer Quantum DX-Series System Unpacking and Installation Instructions Storage array 9 Storage array 13 Installing the DX-Series System Document 6513502-06 A01 October 2006...
  • Page 40 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 11 Starting in the back of the rack, install the AC power sequencers with four Figure 39 Installing the AC Power Sequencers Back of rack Screws AC power sequencer...
  • Page 41: Installing Additional Storage Arrays

    Caution: cables. Do not pinch the cables and keep the connector ends free from debris. 1 Fibre Channel switch ports (see connections (DX100 requires four SFPs plus two for every installed storage array). Installing Additional Storage Arrays Document 6513502-06 A01 October 2006 on page 15.
  • Page 42 Figure 41 Installing the SFP(s) in the Connection Modules 2 Storage array RAID controllers (see cable connections (channel 0 on the top left of the storage array and channel 1 on the upper right of the storage array). Required SFP for controller connection...
  • Page 43 Each storage array has a set of dip switches located on the back of the array in Verifying Storage the upper left-hand corner. The switches are set in manufacturing, but verify Array Dip Switches the settings prior to cabling the system (see...
  • Page 44 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 To cable a DX30 with up to four storage arrays: Cabling a DX30 Table 6 DX30 Fibre Channel and Ethernet Cabling 1 Connect the power cords, LC-to-LC Fibre Channel cables, and Ethernet...
  • Page 45 Storage array 1 Storage array 2 AC Power connector Storage array 3 AC Power connectors Storage array 4 Quantum DX-Series System Unpacking and Installation Instructions Customer network Fibre Channel host(s) Eth1 Eth0 Fibre Channel connection Fibre Channel connection Fibre Channel...
  • Page 46: October

    Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 To cable a DX100 system: Cabling a DX100 Table 7 DX100 Fibre Channel and Ethernet Cabling (Controller to FC Switch) 1 Connect the power cords, LC-to-LC Fibre Channel cables, and Ethernet...
  • Page 47 Table 8 DX100 Fibre Channel and Cabling (Storage Arrays 1 through 8) Quantum DX-Series System Unpacking and Installation Instructions The medium changer (robot) and three virtual tape drives, by Note: default, are presented on port 5 and the remaining three virtual tape drives are presented on port 6.
  • Page 48 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Table 9 DX100 Fibre Channel and Cabling (Storage Arrays 9 through 16) Connection From: Storage array 8 Primary connection module FC- Ch0 (right-hand port) Secondary connection module FC- Ch1 (left-hand port)
  • Page 49 Quantum DX-Series System Unpacking and Installation Instructions Connection From: Storage array 16 Primary connection module FC- Ch0 (right-hand port) Secondary connection module FC- Ch1 (left-hand port) Cabling the DX-Series System Document 6513502-06 A01 October 2006 FC switch 2, port 10...
  • Page 50 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 44 Connecting the DX100 Cables (Eight Storage Arrays 1-4 shown) Controller To primary power sequencer Ethernet switch First Fibre Channel switch Storage array 1 Storage array 2...
  • Page 51 Ethernet switch First Fibre Channel switch Storage array 5 Storage array 6 Storage array 7 Storage array 8 Quantum DX-Series System Unpacking and Installation Instructions Customer network Dual port Fibre Channel HBAs Eth1 Eth0 13 14 15 16 17 18 19 20...
  • Page 52 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 46 Connecting the DX100 Cables (Sixteen Storage Arrays 9-12 shown) Controller To primary power sequencer Ethernet switch Second Fibre Channel switch Storage array 9 Storage array 10...
  • Page 53 Ethernet switch Second Fibre Channel switch Storage array 13 Storage array 14 Storage array 15 Storage array 16 Quantum DX-Series System Unpacking and Installation Instructions Customer network Dual port Fibre Channel HBAs Eth1 Eth0 13 14 15 16 17 18 19 20...
  • Page 54: Configuring The Dx-Series System

    Simply connect the DX30 system AC power connectors (two for the controller and two per storage array) to available grounded outlets using the power cords supplied in the accessory kits. DX100 Power Cabling The DX100 system requires additional AC power sequencers to provide power to the system. • •...
  • Page 55 • • • The power on procedure differs depending on the DX-Series system (DX30 or Turning On the DX-Series DX100). Refer to the following section to turn on the DX-Series system: System • • Turning on the DX30 The DX30 components must be turned on in the following order: •...
  • Page 56 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 49 Storage Array LCD Display Figure 50 Turning on the DX-Series Controller During the DX-Series storage array power on sequence, the LCD screen will indicate that the array is starting up. When all tests are completed,...
  • Page 57 Turning on the DX100 The DX100 must be powered on in the following sequence: • • • Before you can access the web management pages from the DX-Series Initially Configuring the controller, you must initially configure the system with an IP address and...
  • Page 58 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Connecting to the DX-Series Controller To initially configure the DX-Series system: Figure 51 Connecting the Service PC to the DX-Series Controller Configure Service Options To configure the service options:...
  • Page 59 Service Menu Configuring User Options To configure user options: Quantum DX-Series System Unpacking and Installation Instructions 4 Type 3 and press <Enter>. The system prompts you to enter a serial number. 5 Enter the system serial number and press <Enter>.
  • Page 60 Do not use an IP address in the range of 192.168.xx since that Note: address is reserved for the internal control network among the DX100 controller, Fibre Channel switch, and AC power sequencers. The system displays the information and asks for confirmation.
  • Page 61 Quantum DX-Series System Unpacking and Installation Instructions • Type 2 to create cartridges on a SPECIFIED storage array. If this is an upgrade to an existing system, create Caution: cartridges ONLY on the new storage arrays. • Type 3 to create cartridges on a specified RAID set.
  • Page 62 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 For 400GB Drives: For 500GB Drives: If you select , you can create between 1 and 80 cartridges By quantity per RAID set. The capacity decreases the more tape cartridges you create.
  • Page 63 The collect script is included in the DX-Series controller software. It collects status information from the controller and the array so it can be analyzed by Quantum. It is recommended that you run a collect script prior to leaving the customer site.
  • Page 64 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Accessing the DX-Series controller consists of the following steps: Accessing the DX-Series Controller • • Setting Up the Service PC To setup the service laptop to communicate with the DX-Series system: 1 When prompted for a login, enter serviceshell and the <service...
  • Page 65 Connecting the Service PC to the Network Figure 53 Log In Screen Quantum DX-Series System Unpacking and Installation Instructions 1 Connect the service PC to the network switch on the same subnet as the DX-Series controller with an Ethernet cable.
  • Page 66 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 54 License Page 4 Select and type password as the default password. Administrator The passwords must be lower case and limited to 15 Note: characters. Commas (,) and percent signs (%) are NOT valid characters.
  • Page 67 Page Figure 56 Home Screen Quantum DX-Series System Unpacking and Installation Instructions The registration information is sent to Quantum to allow the DX-Series system to be easily serviced and maintained. If you do not want to register on-line, press , then fill out and mail the warranty card Skip included in the DX-Series accessory kit.
  • Page 68: Adding A Partition

    Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Partitioning provides the capability to divide the DX-Series virtual tape drives Adding a Partition and storage elements into separate partitions, usable by separate host computers on the same network. The unassigned tape drives and cartridges as well as all user defined partitions currently configured on the system.
  • Page 69: Configuring The Network Information

    The Default partition contains 6 tape drives at the time of installation, however, you can change the number of drives (DX30 up to 30 tape drives; DX100 up to 55 tape drives). If all tape drives are assigned to other partitions, you must...
  • Page 70 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 10 Return the DX-Series system to the online state from the If you have not configured the network information, configure the network Configuring the information via the following web pages:...
  • Page 71: Configuring The Date And Time

    Configuring the Date correct date and time allows the DX-Series system to provide accurate reports and Time when events occur. Quantum DX-Series System Unpacking and Installation Instructions 2 Edit the configuration information as desired (see description of the fields). Field...
  • Page 72: Configuring The Security Options

    Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 60 Date and Time Configuration To access the Configuring the Security Options 1 In the page, click Configuration The management frame displays the figure 60). 2 There are two options for setting the system date and time:...
  • Page 73 This section allows you to change the passwords for these accounts. To set the monitor and administrator passwords: Quantum DX-Series System Unpacking and Installation Instructions page is divided into two sections: Security Passwords...
  • Page 74 Once you install these components, you can establish a secure connection using the SSL protocol. The Quantum DX-Series system comes with a SSL certificate; however, you can purchase other certificates and add them to the DX-Series SSL configuration.
  • Page 75 The DX-Series system allows you to control and configure the Fibre Channel Configuring the Fibre HBAs that reside in the controller. Channel Settings To configure the Quantum DX-Series System Unpacking and Installation Instructions 3 To add a SSL certificate, click page displays (see Install SSL Certificate 4 Under Upload Your SSL certificate file the new SSL certificate file.
  • Page 76 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 64 Fibre Channel Configuration Table 11 Port Settings The DX-Series system must be off-line to configure the Fibre Note: Channel options. 2 The page (see table 11...
  • Page 77 The Device Mapping page allows you to map or assign DX-Series virtual devices (robot and tape drives) to specific Fibre Channel ports. The default setting for both the DX30 and DX100: • Port 5 is assigned the robot and tape drives 0 through 2.
  • Page 78: Configuring The Email Settings

    Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 To configure the Email settings: Configuring the Email Settings Figure 66 Email Tab 5 When all of the virtual devices have been assigned to the appropriate port, click to accept the port settings.
  • Page 79 To send an email notification to Quantum Send to Corporation as well as the recipients list, select Quantum? the Send to Quantum check box for the specific message type. The company and contact information is sent to Quantum as an attachment to this email.
  • Page 80: Configuring The Snmp Settings

    Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Table 13 Email Server Information If the customer wishes to use the DX-Series system with a network framework Configuring the SNMP application such as HP OpenView or CA Unicenter, the SNMP configuration Settings must be defined.
  • Page 81 Table 14 SNMP Trap Selections Figure 68 SNMP Trap Destinations Quantum DX-Series System Unpacking and Installation Instructions Field Description Informational If selected, Warning If selected, Failure If selected, Available If selected, a trap is generated every time the library transitions from an unavailable to an available state.
  • Page 82 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 69 SNMP Community Management 10 Click Send from the SNMP tab to send a test SNMP trap. Verify that the 8 Under , enter the new community information:...
  • Page 83 Contacts Page Figure 70 Contacts Tab Table 15 Company Information Quantum DX-Series System Unpacking and Installation Instructions 1 To access the page, from the Contacts tab. Contacts The management frame displays the 2 Edit the configuration information as desired and click Apply.
  • Page 84: Enabling Fibre Channel Compression

    Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Table 16 Primary/ Secondary Contact Information To activate the Fibre Channel compression card(s), you must enable the Enabling Fibre Channel feature by entering a license key. Compression To enter the licence key:...
  • Page 85 DX-Series system administrator including: • • Quantum DX-Series System Unpacking and Installation Instructions The management frame displays the 2 Enter the Fibre Channel compression license key in the and click The license key is added to the installed keys list.
  • Page 86: Restarting The System

    Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Figure 72 Downloading Configuration Files The DX-Series system must be restarted to activate the new configuration Restarting the System information. To restart the DX-Series system: 3 Under Download System Configuration File A confirmation message will display, asking whether to open or save the file.
  • Page 87 Figure 73 Shutting Down the DX-Series System Quantum DX-Series System Unpacking and Installation Instructions 3 Under , click System Shutdown The DX-Series reboots. The installation procedure is complete. Configuring the DX-Series System Document 6513502-06 A01 October 2006 Restart...
  • Page 88 Quantum DX-Series System Unpacking and Installation Instructions Document 6513502-06 A01 October 2006 Configuring the DX-Series System...

This manual is also suitable for:

Dx30Dx series

Table of Contents