OBID i-scan
ANNEX D: Index of Status Bytes
Hex-value
0x00
OK:
• Data / parameters have been read or stored without error
• Control command has been executed
Hex-value
0x01
No Transponder:
• No Transponder is located within the detection range of the Reader.
• The Transponder in the detection range has been switched to mute.
• The communication between Reader and Transponder has been interfered and the Reader
is not able to read the Transponder anymore.
0x02
Data False:
CRC16 data error at received data.
0x03
Write-Error:
Negative
• Attempt to write on a read-only storing-area.
• Too much distance between Transponder and Reader antenna.
• Attempt to write in a noise area.
Address-Error:
0x04
The required data are outside of the logical or physical Transponder-address area:
• The address is beyond the max. address space of the Transponder.
• The address is beyond the configured address space of the Transponder.
0x05
Wrong Transponder-type:
This command is not applicable at the Transponder:
• A special command is not applicable to the Transponder.
0X08
Authent Error
• If access password is wrong
Hex-value
0x10
EEPROM-failure:
The EEPROM of the Reader is not able to be written on.
Before writing onto the EEPROM a faulty checksum of parameters has been detected.
0x11
Parameter-Range-Error:
The value range of the parameters was exceeded.
0x13
Login-Request:
Configuration access without having logged in to the Reader before.
Login-Error:
0x14
Login attempt with wrong password.
0x15
Read Protect:
The configuration block is reserved for future use.
0x16
Write Protect:
The configuration block is reserved for future use.
FEIG ELECTRONIC GmbH
plausibility
check of the written data:
Page 119 of 125
Manual
General
Transponder Status

Parameter Status

ID ISC.PRHD102
H71101-2e-ID-B.doc