Maintenance

The maintenance plan is based in years from start-up, hours of charging or
standby, and cycles of charging. Depending on the group of components, it is
necessary to apply a specific maintenance period. Check periods in the next table:
General maintenance
Preventive maintenance**
Control devices
Screen ensemble Raption
Connectors and sockets
CCS Connector
CHAdeMO Connector
CCS holder adjustment
Power
Power modules
Extra power supply (UPS)
Contactors and relays
Switching contactors
Switching relays
Power contactors/relays
Ventilation and heating
Control part fans
Power modules fans
Filters
*
Estimated number of years taking into account a number of 10
daily Charging sessions.
** Raption WearCheck list
*** Depending on the usage conditions such as temperature, load
and charging cycles; the components' useful life could vary.
6 months /
1 year /
2 years /
2K cycles
4K cycles
8K cycles
I
I
-
I
-
I
-
I
I
I
-
I
I
I
-
-
-
-
-
I
-
I
-
I
-
R
R
Years from start-up*
3 years /
4 years /
12K cycles
16K cycles
I
I
I
I
I
I
I
M
I
I
M
I
I
I
I
I
I
I
I
I
I
I
-
I
I
-
I
I
I
R
I
I
I
I
I
I
R
R
Key:
I
Inspection
R
Replacement
M***
Manufacturer component lifecycle reached
-
No maintenance needed
5 years /
Estimated time
20K cycles
(minutes) for service
I
90
Inspection:
30
Replacement:
I
15
Inspection:
45
Replacement:
I
15
Inspection:
45
Replacement:
I
15
Inspection:
I
5
Inspection:
75
Replacement:
I
40
Inspection:
30
Replacement:
M
15
Inspection:
45
Replacement:
R
15
Inspection:
45
Replacement:
R
15
Inspection:
120
Replacement:
I
30
Inspection:
120
Replacement:
M
30
Inspection:
60
Replacement:
M
15
Inspection:
R
45
Replacement:
78

Advertisement