With a few line breaks it can be turned into a more familiar look:
Nov 8 09:39:18 raption user.info pss[306]: ------------------- VECTOR OF ERROR FLAGS OBJECTS -------------------
Error Flags Object -> Module Type: 31,
Name: CCS2 Error flags: 0000 0000 0000 0000 0000 0000 0000 0020
Historical error flags: 0000 0000 0000 0000 0000 0000 0000 0120
Predecessor errors: 0 - 0
Status message flags: 0000 0000 0000 0000 0000 0001 0000 0001
Historical status message flags: 0000 0000 0000 0000 0000 0001 0000 0001
Predecessor status messages: 0 - 0 State machines: 701 700 2080 80 1 0 701 700 1080 80 1203
Nov 8 09:39:18 raption user.info pss[311]: ------------------- VECTOR OF ERROR FLAGS OBJECTS -------------------
Error Flags Object -> Module Type: 10,
Name: Converter Error flags: 0000 0000 0000 0000 0000 0000 0000 0000
Historical error flags: 0000 0009 0000 0000 0000 0000 0000 4000
Predecessor errors: 0 - 0 Status message flags: 0000 0000 0000 0000 0000 0000 0000 0000
Historical status message flags: 0000 0000 0000 0000 0000 0000 0000 0000
Predecessor status messages: 0 - 0 State machines: 2 803 802 801 800 0 0 0 0 0 0
At first, it is shown the part of the error related with the Connector and then, the
Converter error. Same format as in the Display, which can be easily decoded.
70
Need help?
Do you have a question about the Raption 150 Compact CCS and is the answer not in the manual?
Questions and answers