Raption 150 Compact Service Manual
Notifying Boot - -1
There is some kind of filter on the network related with the size of the messages
sent from the charger, maybe in the simcard provider side or in the CS. This
filter cause that the message, or part of the message is not sent to the CS, so
information is not completely delivered. That problem can be solved adjusting the
MTU to a lower value. Default value is 1500, and a good solution would be to adjust
it to 1000 or 1200 bytes. In this way problem is solved as messages size is lower
than the filter.
Teltonika RUT240 allows you to adjust this paramter in the Network<Mobile
section.
Ask Simcard provider to adjust the MTU value to 1000 or 1200 bytes.
HTTP/1.1 404 Not Found
Charger reaches the CS and could not logged in:
The Host URL introduced is not correct. Please, review and make sure it is
properly written. Take into account that it is case sensitive:
http://ip_address:8080/html/setup.html
SSL/TLS error
HTTPS URL's requires a certificate that must to be uploaded to the OCPP
integrations webpage.
The Certificate uploaded is not correct.
Time and Date are not correctly synchronised
Getting valid public ID timeout
The password of the modem (f.e. Admin001 in Teltonika Rut240) has been
changed. It cannot be changed.
Check the list of Blocked IPs of the modem. If IP of the charger is included
there, remove it from the list.